Motion-to-Risk: Physics-Guided Multi-Source State Assessment for High-Voltage Vacuum Circuit Breakers
Electronics · 12.08.2026 · 15 (16) · 3582
DOI: 10.3390/electronics15163582 ↗Kurz gefasst
Fachartikel in der Zeitschrift Electronics, online erschienen am 12.08.2026. Verfasst von Song Gao und 5 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Henan Province, Program for Science and Technology Innovation Talents in the University of Henan Province.
Abstract (Originalsprache)
High-voltage vacuum circuit breakers are critical switching devices in power systems, and their reliable condition assessment is essential for safe operation and maintenance decision-making. However, breaker abnormalities are often reflected by heterogeneous operation-related evidence, and existing methods based on single-source measurements or generic feature fusion may weaken source-specific diagnostic roles and limit the recognition of compound abnormal conditions. To address this problem, this paper proposes the Physics-Guided Multi-Source State Assessment Network (PMSA-Net), a reliability-aware framework that integrates mechanical motion, opening- and closing-position limit events, and infrared thermography. Source-specific encoders first extract dynamic, end-position, and thermal representations. Reliability-aware Asymmetric Selective Interaction (RASI) then calibrates primary and auxiliary evidence, using mechanical motion as the operational context and the other sources as complementary constraints. Thermal Frequency-aware Selective Modulation (TFSM) stabilizes the low-frequency thermal field and enhances high-frequency hotspot responses. Task-conditioned evidence allocation jointly predicts state category, travel anomaly, limit-event consistency, thermal risk, and overall risk. On a laboratory-simulated benchmark covering 15 operating conditions, PMSA-Net achieved 90.18±0.36% state-category accuracy and an 80.00±0.50% overall-risk macro-F1 score over five independent runs. Under cross-source abnormalities, it exceeded the variational-fusion baseline by 2.59 and 3.05 percentage points on these metrics, respectively. These results indicate that reliability-aware calibration improves multi-task assessment of compound breaker abnormalities.
Förderung
- Natural Science Foundation of Henan Province
- Program for Science and Technology Innovation Talents in the University of Henan Province
Zitieren
APA
Gao, S., Zhang, K., Jin, X., Wang, H., Zhao, Z., & Wang, H. (2026). Motion-to-Risk: Physics-Guided Multi-Source State Assessment for High-Voltage Vacuum Circuit Breakers. Electronics, 15(16), 3582. https://doi.org/10.3390/electronics15163582
Vancouver
Gao S, Zhang K, Jin X, Wang H, Zhao Z, Wang H. Motion-to-Risk: Physics-Guided Multi-Source State Assessment for High-Voltage Vacuum Circuit Breakers. Electronics. 2026;15(16):3582. doi:10.3390/electronics15163582
BibTeX
@article{Gao2026,
author = {Gao, Song and Zhang, Kaikai and Jin, Xin and Wang, Hui and Zhao, Zengjie and Wang, Huan},
title = {Motion-to-Risk: Physics-Guided Multi-Source State Assessment for High-Voltage Vacuum Circuit Breakers},
journal = {Electronics},
year = {2026},
volume = {15},
number = {16},
pages = {3582},
doi = {10.3390/electronics15163582}
}
EUVIMED