EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Real-Time Neuroadaptive Control with Tactile Calibration for Physical Human–Robot Interaction

Ashutosh Prakash, Mohamed A. Hanafy, Jordan Dowdy, Dan O. Popa

Electronics · 2026-07-19 · 15 (14) · 3173

DOI: 10.3390/electronics15143173 ↗

At a glance

Journal article in Electronics, published online on 2026-07-19. Written by Ashutosh Prakash and 3 co-authors. 51 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Science Foundation (NSF) EPSCoR.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

We present a neuroadaptive control framework applied to a tactile sensing interface for real-time, human-guided physical interaction with a robotic arm. The framework employs a dual-loop architecture consisting of an inner-loop neuroadaptive controller that compensates for nonlinear robot dynamics and an outer-loop ARMA–RLS tactile mapping that converts tactile sensor voltages into planar end-effector displacement commands. Four piezoresistive tactile sensors mounted on the robot end-effector are calibrated individually using autoregressive moving-average (ARMA) models updated through recursive least squares (RLS). The proposed tactile interface does not estimate an absolute Cartesian force/torque wrench; instead, it learns a user- and sensor-specific voltage-to-motion command mapping for planar guidance. To evaluate robustness to user variability, 28 participants completed the calibration experiments, producing 112 user- and sensor-specific calibration models. The calibration procedure achieved millimeter-level displacement-prediction accuracy, with a mean RMSE of approximately 2.70 mm across participants. After calibration, participants used the tactile interface to guide the robot along a predefined figure-eight trajectory. The average nearest-path tracking error decreased from 11.07±5.45 mm in the initial trial to 8.41±3.48 mm in the final trial, indicating improved tactile-guided path following after repeated exposure to the interface. During these experiments, the inner neuroadaptive controller maintained bounded joint-space tracking errors. Overall, the proposed calibration and control framework provides a low-cost physical interface for planar human-guided robot motion without requiring a wrist-mounted force/torque sensor.

Funding

  • National Science Foundation (NSF) EPSCoR

Cite

APA

Prakash, A., Hanafy, M. A., Dowdy, J., & Popa, D. O. (2026). Real-Time Neuroadaptive Control with Tactile Calibration for Physical Human–Robot Interaction. Electronics, 15(14), 3173. https://doi.org/10.3390/electronics15143173

Vancouver

Prakash A, Hanafy MA, Dowdy J, Popa DO. Real-Time Neuroadaptive Control with Tactile Calibration for Physical Human–Robot Interaction. Electronics. 2026;15(14):3173. doi:10.3390/electronics15143173

BibTeX
@article{Prakash2026,
  author = {Prakash, Ashutosh and Hanafy, Mohamed A. and Dowdy, Jordan and Popa, Dan O.},
  title = {Real-Time Neuroadaptive Control with Tactile Calibration for Physical Human–Robot Interaction},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {14},
  pages = {3173},
  doi = {10.3390/electronics15143173}
}
Start for free →