EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Calibration-Based Primary-Side Identification of Coupling and Load Resistance for the Control of a Low-Power Wireless Charger Without Secondary-to-Primary Communication

Víctor Hueros, Álvaro Pérez, Cristina Fernandez, Andrés Barrado

Electronics · 2026-07-17 · 15 (14) · 3159

DOI: 10.3390/electronics15143159 ↗

At a glance

Journal article in Electronics, published online on 2026-07-17. Written by Víctor Hueros and 3 co-authors. 25 references. The full text is freely available (open access, CC BY 4.0). Funded by: Regional Council of Science, Universities and Innovation of the Community of Madrid.

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

Wireless power transfer (WPT) technology offers reliability, safety, and ease of use for low-power charging applications. However, output regulation is difficult when the secondary side is inaccessible, because the magnetic coupling factor k and the equivalent load resistance RL may both be unknown and variable. This work addresses the two unknown parameters problem using only primary-side measurements of the DC-link voltage VDC and the primary resonant current I1. An initial calibration stage temporarily connects a known resistance on the receiver side, making it possible to estimate k without a secondary-to-primary communication link. Then, during the charging stage, the previously estimated coupling is used to estimate the equivalent load resistance and to indirectly regulate the charger input voltage through a primary-side pre-regulator. The proposed system is intended for low-power WPT chargers, in which the receiver side must be simple and compact. A resonant DC converter prototype was experimentally implemented using a Class-E inverter, a Series-Series compensation network, a full-bridge rectifier, primary-side voltage/current sensing, and a pre-regulator. The experimental results show a maximum coupling identification error of 3.9% and a maximum load-resistance identification error of 10.67%. The resulting output voltage is not measured directly at the load; instead, it is estimated from primary-side variables and maintained within the 4–6 V input window of the target charger around a 5 V reference, with a maximum relative voltage error of approximately 10%. The work therefore presents a primary-side identification and control proof of concept without secondary-to-primary communication, while explicitly discussing the calibration requirement, equivalent-load validation, efficiency limitations, and the conditions under which recalibration would be required.

Funding

  • Regional Council of Science, Universities and Innovation of the Community of Madrid

Cite

APA

Hueros, V., Pérez, Á., Fernandez, C., & Barrado, A. (2026). Calibration-Based Primary-Side Identification of Coupling and Load Resistance for the Control of a Low-Power Wireless Charger Without Secondary-to-Primary Communication. Electronics, 15(14), 3159. https://doi.org/10.3390/electronics15143159

Vancouver

Hueros V, Pérez Á, Fernandez C, Barrado A. Calibration-Based Primary-Side Identification of Coupling and Load Resistance for the Control of a Low-Power Wireless Charger Without Secondary-to-Primary Communication. Electronics. 2026;15(14):3159. doi:10.3390/electronics15143159

BibTeX
@article{Hueros2026,
  author = {Hueros, Víctor and Pérez, Álvaro and Fernandez, Cristina and Barrado, Andrés},
  title = {Calibration-Based Primary-Side Identification of Coupling and Load Resistance for the Control of a Low-Power Wireless Charger Without Secondary-to-Primary Communication},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {14},
  pages = {3159},
  doi = {10.3390/electronics15143159}
}
Start for free →