EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Harmonic Suppression in Active-Clamped High-Frequency Link Inverters Under Non-Unity Power Factor Loads

Bowen Gu, Shuang Rong, Wanlin Guan, Huaiyu Guo, Chen Yang, Fangang Meng, Zhipeng Liu, Xueting Lei, Mingjiang Zhang, Yuanting Hu, Pengju Zhang, Yifan Dong und 4 weitere

Electronics · 03.07.2026 · 15 (13) · 2919

DOI: 10.3390/electronics15132919 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 03.07.2026. Verfasst von Bowen Gu und 15 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Corporation of China Technology Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-frequency link inverters (HFLI) inherently suffer from voltage ringing, and the issue becomes more severe under non-unity power factor loads. Although active clamping circuits can effectively suppress the voltage ringing, they cause severe distortion in the output voltage and current waveforms under such loads. To address this problem, this paper proposes an improved modulation strategy with leakage energy feedback for active-clamped high-frequency link inverters (ACHFLI). In the proposed strategy, two secondary-side MOSFETs achieve zero-current switching (ZCS) turn-off, while the other two MOSFETs operate at low frequency throughout the entire line cycle. By feeding the leakage inductance energy back to the primary side, the voltage balance of the clamping capacitor can be better maintained under non-unity power factor loads, thereby mitigating the waveform distortion in the output voltage and current during the intervals when their polarities are opposite. A prototype with 48 Vin input, 110 Vo output, and 300 W rated power was built to verify the proposed strategy. Experimental results show that the modulation strategy alleviates the waveform distortion when the voltage and current have opposite polarities, and the total harmonic distortion (THD) of the output voltage is reduced by a maximum of 2.74%.

Förderung

  • State Grid Corporation of China Technology Project

Zitieren

APA

Gu, B., Rong, S., Guan, W., Guo, H., Yang, C., Meng, F., Liu, Z., Lei, X., Zhang, M., Hu, Y., Zhang, P., Dong, Y., Liu, Z., Zheng, J., Chen, H., & Zhou, R. (2026). Harmonic Suppression in Active-Clamped High-Frequency Link Inverters Under Non-Unity Power Factor Loads. Electronics, 15(13), 2919. https://doi.org/10.3390/electronics15132919

Vancouver

Gu B, Rong S, Guan W, Guo H, Yang C, Meng F, et al. Harmonic Suppression in Active-Clamped High-Frequency Link Inverters Under Non-Unity Power Factor Loads. Electronics. 2026;15(13):2919. doi:10.3390/electronics15132919

BibTeX
@article{Gu2026,
  author = {Gu, Bowen and Rong, Shuang and Guan, Wanlin and Guo, Huaiyu and Yang, Chen and Meng, Fangang and Liu, Zhipeng and Lei, Xueting and Zhang, Mingjiang and Hu, Yuanting and Zhang, Pengju and Dong, Yifan and Liu, Zhiyang and Zheng, Jun and Chen, Hongyu and Zhou, Rui},
  title = {Harmonic Suppression in Active-Clamped High-Frequency Link Inverters Under Non-Unity Power Factor Loads},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {13},
  pages = {2919},
  doi = {10.3390/electronics15132919}
}
Kostenlos starten →