EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

OHRC-ESO-ADECC for Harmonic Suppression in LCL–LC Grid-Tied Inverters Under Distorted Grid Voltages

Zhengkai Lv, Ning Wang, Haojun Wu

Electronics · 18.11.2026 · 15 (22) · 5382

DOI: 10.3390/electronics15225382 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 18.11.2026. Verfasst von Zhengkai Lv und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

LCL–LC filters attenuate switching-frequency harmonics, but distorted grid voltages still induce low-order harmonic currents. Combining repetitive compensation with a higher-order filter also requires an implementable inverse and a stability analysis that retains the controller’s internal dynamics. This paper develops an odd-harmonic repetitive control (OHRC) and extended state observer (ESO)-based active disturbance estimation–compensation controller (OHRC-ESO-ADECC) for this problem. Its contribution is a discrete realization in which the predictor, correction, and voltage-command sequence defines the internal compensation channel. Half-period memory permits causal finite approximation of its nonminimum-phase inverse, while complete-mode analysis relates inverse length to the limits of closed-loop decay. At 5 kHz, averaged-model comparisons use the same harmonic-admittance objective, stability test, and noise budget. At the original benchmark budget, the selected five-term inverse reduces the objective from 19.071 to 12.550 mA/V relative to the selected phase-lead compensator, a 34.2% reduction, with higher calculated noise gain. Tighter budgets can instead favor phase lead. Hardware records compare four controller architectures during grid-voltage and current-reference steps; recovery rankings depend on the evaluation tolerance. The results provide a constraint-based selection procedure that balances harmonic-current suppression, recovery, noise amplification, and implementation cost rather than an unconditional preference for a longer inverse.

Zitieren

APA

Lv, Z., Wang, N., & Wu, H. (2026). OHRC-ESO-ADECC for Harmonic Suppression in LCL–LC Grid-Tied Inverters Under Distorted Grid Voltages. Electronics, 15(22), 5382. https://doi.org/10.3390/electronics15225382

Vancouver

Lv Z, Wang N, Wu H. OHRC-ESO-ADECC for Harmonic Suppression in LCL–LC Grid-Tied Inverters Under Distorted Grid Voltages. Electronics. 2026;15(22):5382. doi:10.3390/electronics15225382

BibTeX
@article{Lv2026,
  author = {Lv, Zhengkai and Wang, Ning and Wu, Haojun},
  title = {OHRC-ESO-ADECC for Harmonic Suppression in LCL–LC Grid-Tied Inverters Under Distorted Grid Voltages},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {22},
  pages = {5382},
  doi = {10.3390/electronics15225382}
}
Kostenlos starten →