Journal article in Electronics, published online on 2026-06-03. Written by Purva Talegaonkar and 10 co-authors. 28 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Science Foundation.

SantraukaBibliografiniai duomenysCiteRelated studies

Abstract (original language)

Accurate and unobtrusive measurement of upper-limb kinematics is critical for advancing wearable sensing technologies used in industrial ergonomics, human–machine interaction, and real-time biomechanics monitoring. This study evaluates the performance of two soft, flexible wearable sensors—BendLabs biaxial angular displacement sensors and StretchSense capacitive stretch sensors—for quantifying wrist and elbow motions during simulated dynamic industrial tasks. Wrist flexion–extension and radial–ulnar deviation were measured using BendLabs sensors mounted on the dorsal hand, while elbow flexion–extension was captured using StretchSense sensors positioned along the elbow joint. A multi-camera optical motion capture system served as the reference standard. Sensor data were preprocessed using baseline correction, smoothing, denoising, and normalized cross-correlation techniques to support temporal alignment with motion-capture recordings. Across all activities, the BendLabs sensors demonstrated moderate agreement with motion capture for wrist kinematics, with generally better performance for radial–ulnar deviation than for flexion–extension. StretchSense sensors demonstrated stronger agreement with motion capture for elbow flexion–extension, with performance that was generally consistent across task types. These findings support the feasibility of soft wearable sensors for capturing upper-limb kinematics during simulated occupational tasks and highlight their potential for integration into ergonomic assessment, occupational monitoring systems, and future industrial wearable platforms.

Funding

  • National Science Foundation

Cite

APA

Talegaonkar, P., Saucier, D., Khaled, L. B., Tillery, E., Turner, A. J., Lowell, R., Weinstein, J., Ball, J. E., Chander, H., Smith, B. K., & V, R. F. B. (2026). Validation of Soft Wearable Sensors for Wrist and Elbow Kinematics During Simulated Industrial Tasks. Electronics, 15(11), 2453. https://doi.org/10.3390/electronics15112453

Vancouver

Talegaonkar P, Saucier D, Khaled LB, Tillery E, Turner AJ, Lowell R, et al. Validation of Soft Wearable Sensors for Wrist and Elbow Kinematics During Simulated Industrial Tasks. Electronics. 2026;15(11):2453. doi:10.3390/electronics15112453

BibTeX
@article{Talegaonkar2026,
  author = {Talegaonkar, Purva and Saucier, David and Khaled, Laith Bani and Tillery, Erin and Turner, Alana J. and Lowell, Russell and Weinstein, James and Ball, John E. and Chander, Harish and Smith, Brian K. and V, Reuben F. Burch},
  title = {Validation of Soft Wearable Sensors for Wrist and Elbow Kinematics During Simulated Industrial Tasks},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {11},
  pages = {2453},
  doi = {10.3390/electronics15112453}
}
Start for free →