EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Resonance Mechanism Analysis and Suppression of Grid-Connected Energy Storage Power Station Inverter

Weiheng Kuang, Jinchuan Guo, Lianhui Ning, Junyuan Zhang, Xinmei Gu, Sisi Chen, Shihong Shi, Weihan Hao, Min Zhou, Tiantian He, Qingxin Wang

Electronics · 21.05.2026 · 15 (10) · 2221

DOI: 10.3390/electronics15102221 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 21.05.2026. Verfasst von Weiheng Kuang und 10 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, Science and Technology Project of China Energy Engineering Group Guangdong Electric Power Design Institute Co., Ltd..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasingly prominent “double-high” characteristics (high penetration of renewable energy and high proportion of power electronic devices) in modern power systems pose severe challenges to secure and stable operation, especially due to wideband oscillations induced by grid-connected inverters. In view of the fact that existing impedance modeling for grid-forming control often neglects the decoupling effect of the LC filter capacitor and the dynamics of inner voltage/current loops, leading to inaccurate characterization of mid-to-high frequency impedance, this paper aims to establish more accurate impedance models for grid-connected inverters and to develop effective oscillation mitigation methods accordingly. First, the harmonic linearization method is adopted to derive refined positive- and negative-sequence impedance analytical models for NPC inverters under both grid-following and grid-forming control. Second, simulation-based frequency scanning is conducted to validate the accuracy of the proposed models, and the differences in system resonance characteristics under the two control modes are comparatively analyzed. Finally, oscillation suppression strategies based on active damping and virtual impedance are, respectively, designed. The results show that the proposed models can accurately characterize mid-to-high frequency impedance, reveal the distinct resonance mechanisms of different control modes, and the proposed suppression strategies can effectively attenuate wideband oscillations. These findings provide theoretical foundations and practical technical pathways for stability analysis and optimization design of inverter-grid systems in high-renewable-penetration scenarios.

Förderung

  • National Key Research and Development Program of China
  • Science and Technology Project of China Energy Engineering Group Guangdong Electric Power Design Institute Co., Ltd.

Zitieren

APA

Kuang, W., Guo, J., Ning, L., Zhang, J., Gu, X., Chen, S., Shi, S., Hao, W., Zhou, M., He, T., & Wang, Q. (2026). Resonance Mechanism Analysis and Suppression of Grid-Connected Energy Storage Power Station Inverter. Electronics, 15(10), 2221. https://doi.org/10.3390/electronics15102221

Vancouver

Kuang W, Guo J, Ning L, Zhang J, Gu X, Chen S, et al. Resonance Mechanism Analysis and Suppression of Grid-Connected Energy Storage Power Station Inverter. Electronics. 2026;15(10):2221. doi:10.3390/electronics15102221

BibTeX
@article{Kuang2026,
  author = {Kuang, Weiheng and Guo, Jinchuan and Ning, Lianhui and Zhang, Junyuan and Gu, Xinmei and Chen, Sisi and Shi, Shihong and Hao, Weihan and Zhou, Min and He, Tiantian and Wang, Qingxin},
  title = {Resonance Mechanism Analysis and Suppression of Grid-Connected Energy Storage Power Station Inverter},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {10},
  pages = {2221},
  doi = {10.3390/electronics15102221}
}
Kostenlos starten →