Faulty Line Selection Method Based on Differentiation of Zero-Sequence Current Characteristics for Flexible Grounding Systems

Yafeng Huang, Junhang Ye, Jiaqing Sun

Electronics · 21.04.2026 · 15 (8) · 1754

DOI: 10.3390/electronics15081754 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 21.04.2026. Verfasst von Yafeng Huang und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To effectively address the challenge of faulty line selection during high-impedance grounding faults in distribution networks with a flexible grounding system, a novel fault line selection method that integrates both the amplitude and phase characteristics of zero-sequence currents is proposed. The characteristics of zero-sequence currents under single-phase grounding faults in a flexible grounding system are thoroughly investigated, with a particular focus on analyzing the phase relationship and amplitude differences between the zero-sequence currents of each feeder and that of the neutral point. Upon the switching of the parallel low-resistance device, the zero-sequence current of the faulty line is approximately equal in amplitude but opposite in phase to that of the neutral point. In contrast, the zero-sequence current amplitude of a healthy line is significantly smaller than that of the neutral point, and its phase is nearly orthogonal to the neutral point zero-sequence current. To capture these characteristic differences, the projection of each line’s zero-sequence current onto the neutral point zero-sequence current is employed. A projection coefficient criterion is subsequently constructed to enhance the reliability of line selection. Furthermore, by utilizing the neutral point zero-sequence current, the method can effectively extract the weak zero-sequence current of healthy lines, thereby mitigating the risk of misjudgment by the fault line selection device caused by the inability of zero-sequence current transformers (CT) to accurately acquire such faint signals. Simulation results obtained via PSCAD validate that the proposed method remains effective for single-phase grounding faults with transition resistances up to 3000 Ω, even under extreme operating conditions such as reverse polarity of zero-sequence CT or the presence of strong noise interference.

Zitieren

APA

Huang, Y., Ye, J., & Sun, J. (2026). Faulty Line Selection Method Based on Differentiation of Zero-Sequence Current Characteristics for Flexible Grounding Systems. Electronics, 15(8), 1754. https://doi.org/10.3390/electronics15081754

Vancouver

Huang Y, Ye J, Sun J. Faulty Line Selection Method Based on Differentiation of Zero-Sequence Current Characteristics for Flexible Grounding Systems. Electronics. 2026;15(8):1754. doi:10.3390/electronics15081754

BibTeX
@article{Huang2026,
  author = {Huang, Yafeng and Ye, Junhang and Sun, Jiaqing},
  title = {Faulty Line Selection Method Based on Differentiation of Zero-Sequence Current Characteristics for Flexible Grounding Systems},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {8},
  pages = {1754},
  doi = {10.3390/electronics15081754}
}
Kostenlos starten →