EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Open-Circuit Fault Location Method of Lightweight Modular Multilevel Converter for Deloading Operation of Offshore Wind Power

Zhehao Fang, Haoyang Cui

Electronics · 2026-03-18 · 15 (6) · 1277

DOI: 10.3390/electronics15061277 ↗

At a glance

Journal article in Electronics, published online on 2026-03-18. Written by Zhehao Fang and 1 co-authors. Cited 1 times so far (Crossref); 19 references. The full text is freely available (open access, CC BY 4.0). Funded by: Natural Science Foundation of Shanghai.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

In offshore wind farms, modular multilevel converters (MMCs) may operate under a deloading condition to accommodate wind-speed volatility and dispatch constraints. Here, deloading is defined as transmitted power < 0.2 pu (scenario S2, low-power non-reversal). Under this condition, submodule capacitor-voltage fault signatures are weak and exhibit strong operating-point-dependent drift, which degrades conventional threshold-based or offline-trained methods. We propose a lightweight switch-level IGBT open-circuit fault localization framework for deloaded MMCs. Wavelet packet decomposition is used to extract time–frequency energy features, and principal component analysis reduces feature dimensionality for lightweight deployment. An enhanced XGBoost model further integrates severity-index weighting to alleviate class imbalance and incremental learning to adapt to condition drift induced by wind-power fluctuations. MATLAB2024b/Simulink results show 99.6% accuracy in S2 with less than 2 ms inference latency, and robust performance in extended scenarios including partial-power operation and power reversal.

Funding

  • Natural Science Foundation of Shanghai

Cite

APA

Fang, Z., & Cui, H. (2026). Open-Circuit Fault Location Method of Lightweight Modular Multilevel Converter for Deloading Operation of Offshore Wind Power. Electronics, 15(6), 1277. https://doi.org/10.3390/electronics15061277

Vancouver

Fang Z, Cui H. Open-Circuit Fault Location Method of Lightweight Modular Multilevel Converter for Deloading Operation of Offshore Wind Power. Electronics. 2026;15(6):1277. doi:10.3390/electronics15061277

BibTeX
@article{Fang2026,
  author = {Fang, Zhehao and Cui, Haoyang},
  title = {Open-Circuit Fault Location Method of Lightweight Modular Multilevel Converter for Deloading Operation of Offshore Wind Power},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {6},
  pages = {1277},
  doi = {10.3390/electronics15061277}
}