EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fault-Tolerant Operation of Photovoltaic Systems Using Quasi-Z-Source Boost Converters: A Hardware-in-the-Loop Validation with Typhoon HIL

Basit Ali, Mothana S. A. Al Sunjury, Adnan Ashraf, Mohammad Meraj, Pietro Tricoli

Electronics · 21.06.2025 · 14 (13) · 2522

DOI: 10.3390/electronics14132522 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronics, online erschienen am 21.06.2025. Verfasst von Basit Ali und 4 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photovoltaic (PV) systems are prone to different types of faults, primarily electrical faults such as line-to-ground (L-G) and line-to-line (L-L) faults, which can significantly reduce system performance, efficiency, and lead to increased power losses. Moreover, mechanical damage caused by environmental stressors (such as wind, hail, or temperature variations), aging, or improper installation also contribute to system degradation. This study specifically focuses on electrical faults and proposes a method that not only enables the isolation of faulty modules but also ensures the uninterrupted operation of the remaining healthy modules and also assists in the localization of faults. Unlike benchmarked techniques-based boost converters, the Quasi-Z-Source Boost Converter (QZBC) topology offers improved voltage boosting with high gain values, reduced component stress, and enhanced reliability when the PV system is undergoing fault identification and localization algorithms. A 600-watt PV system connected with a Quasi-Z-Source Boost Converter was implemented and tested under different fault conditions using a hardware-in-the-loop (HIL) setup with Typhoon HIL. All the component values of the QZBC were calculated based on the system requirements rather than assumed, ensuring both practical feasibility and design accuracy. The experimental results show that the converter achieved an efficiency of over 96% under electrical-fault conditions, confirming the effectiveness of the quasi-Z-source boost converter in maintaining a stable power output when the PV system is undergoing fault identification and localization algorithms. The study further highlights the benefits of HIL-based testing for evaluating PV-system resilience and fault-handling capabilities in real-time conditions using a Typhoon HIL 404 environment.

Zitieren

APA

Ali, B., Sunjury, M. S. A. A., Ashraf, A., Meraj, M., & Tricoli, P. (2025). Fault-Tolerant Operation of Photovoltaic Systems Using Quasi-Z-Source Boost Converters: A Hardware-in-the-Loop Validation with Typhoon HIL. Electronics, 14(13), 2522. https://doi.org/10.3390/electronics14132522

Vancouver

Ali B, Sunjury MSAA, Ashraf A, Meraj M, Tricoli P. Fault-Tolerant Operation of Photovoltaic Systems Using Quasi-Z-Source Boost Converters: A Hardware-in-the-Loop Validation with Typhoon HIL. Electronics. 2025;14(13):2522. doi:10.3390/electronics14132522

BibTeX
@article{Ali2025,
  author = {Ali, Basit and Sunjury, Mothana S. A. Al and Ashraf, Adnan and Meraj, Mohammad and Tricoli, Pietro},
  title = {Fault-Tolerant Operation of Photovoltaic Systems Using Quasi-Z-Source Boost Converters: A Hardware-in-the-Loop Validation with Typhoon HIL},
  journal = {Electronics},
  year = {2025},
  volume = {14},
  number = {13},
  pages = {2522},
  doi = {10.3390/electronics14132522}
}
Kostenlos starten →