EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multi-Frequency Electrical Response of a Planar Interdigital Capacitive Sensor for Honey–Syrup Mixture Assessment

Boonyiam Yosrueangsak, Yanapat Songthong, Niwat Angkawisittpan, Somchat Sonasang, Thanatep Phatungthane

Electronic Materials · 06.11.2026 · 7 (4) · 30

DOI: 10.3390/electronicmat7040030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electronic Materials, online erschienen am 06.11.2026. Verfasst von Boonyiam Yosrueangsak und 4 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A planar copper-on-epoxy interdigital capacitor (IDC) was investigated as a direct multi-frequency electrical transducer for assessing honey–syrup mixtures. Eleven syrup volume fractions from 0% to 100% (v/v), each prepared separately at a total volume of 200 mL, were measured at 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, and 2 MHz using a MATRIX MCR-8200H LCR meter in parallel-capacitance/dissipation-factor (Cp–D) mode. Thirty repeated measurement cycles were performed at each composition and frequency and averaged, and the measured Cp was treated as the equivalent response of the complete IDC–sample system. Among the six frequencies, 1 kHz showed the strongest individual linear relation with syrup volume fraction. Under leave-one-out cross-validation, the 1 kHz linear model yielded R2=0.9325, RMSE = 8.22 percentage points, and MAE = 7.34 percentage points. Six-frequency PLSR did not improve prediction, whereas SVR achieved R2=0.9519, RMSE = 6.93 percentage points, and MAE = 5.66 percentage points. In a matched-model comparison using the same nested LOOCV procedure, a 1 kHz SVR yielded R2=0.6928, RMSE = 17.53 percentage points, and MAE = 11.08 percentage points, whereas the six-frequency SVR retained the lower error. The six-frequency SVR produced numerically lower internal cross-validation errors than the 1 kHz linear reference; however, because the analysis contains only eleven independent concentration-level observations, this difference is treated as descriptive rather than as evidence of statistical superiority. Because the analysis is based on eleven concentration-level observations from one preparation series, further validation with independently prepared batches is required to establish between-batch reproducibility and external predictive performance.

Zitieren

APA

Yosrueangsak, B., Songthong, Y., Angkawisittpan, N., Sonasang, S., & Phatungthane, T. (2026). Multi-Frequency Electrical Response of a Planar Interdigital Capacitive Sensor for Honey–Syrup Mixture Assessment. Electronic Materials, 7(4), 30. https://doi.org/10.3390/electronicmat7040030

Vancouver

Yosrueangsak B, Songthong Y, Angkawisittpan N, Sonasang S, Phatungthane T. Multi-Frequency Electrical Response of a Planar Interdigital Capacitive Sensor for Honey–Syrup Mixture Assessment. Electronic Materials. 2026;7(4):30. doi:10.3390/electronicmat7040030

BibTeX
@article{Yosrueangsak2026,
  author = {Yosrueangsak, Boonyiam and Songthong, Yanapat and Angkawisittpan, Niwat and Sonasang, Somchat and Phatungthane, Thanatep},
  title = {Multi-Frequency Electrical Response of a Planar Interdigital Capacitive Sensor for Honey–Syrup Mixture Assessment},
  journal = {Electronic Materials},
  year = {2026},
  volume = {7},
  number = {4},
  pages = {30},
  doi = {10.3390/electronicmat7040030}
}
Kostenlos starten →