EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dual-Band Planar Microwave Solid Complex Dielectric Constant Sensor System Based on E-Interdigital Structure

Haoyang Shi iD, Xuchun Zhang iD, Lin Huang iD, Kun Wang iD, Zanyang Wang iD

Sensors · 17.09.2025 · 25 (18) · 5789

DOI: 10.3390/s25185789 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 17.09.2025. Verfasst von Haoyang Shi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Air Defense and Anti-Missile Academy, Air Force Engineering University, Xi'an 710043, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper introduces a dual-band planar microwave sensor system for measuring the complex dielectric constant of solid material. The sensor system comprises three constituent parts: the sensing probe, the circuit module and the broadband coupler. The sensing probe is composed of a host part and a sensing area. The host part is composed of a microstrip line, which facilitates system integration with other planar microwave components. The sensing area comprises two pairs of E-interdigital structures, which were originally developed from the interdigital capacitor. This configuration manifests two resonant frequency points, specifically 3 GHz and 3.92 GHz. Consequently, any environmental effects exhibit equivalent variation at both resonant frequency points, thereby substantiating the efficacy of the proposed sensor system for differential operation, which has the capacity to mitigate the impact of environmental conditions. The circuit module comprises a controller, two detectors and a signal generator, which facilitate the generation and processing of radio frequency signals within the system. The function of the broadband coupler is to differentiate between the incident signal and the reflected signal. The operating principle is predicated on the variation in the resonant frequency and peak attenuation with respect to the complex dielectric constant of the material under test (MUT). In order to validate the effectiveness of the proposed sensor system, a prototype is fabricated and tested. The proposed sensor system is distinguished by its high sensitivity and low cost. The apparatus is capable of performing measurements independently and without the necessity for auxiliary equipment.

Schlagwörter

Stichwörter der Autor:innen

complex dielectric constantdual-bandmicrowave sensorsensor system

Autor:innen und Institutionen

  • Air Defense and Anti-Missile Academy, Air Force Engineering University, Xi'an 710043, China.

ORCID-Profile: Haoyang Shi, Xuchun Zhang, Lin Huang, Kun Wang, Zanyang Wang

Zitieren

APA

Shi, H., Zhang, X., Huang, L., Wang, K., & Wang, Z. (2025). Dual-Band Planar Microwave Solid Complex Dielectric Constant Sensor System Based on E-Interdigital Structure. Sensors, 25(18), 5789. https://doi.org/10.3390/s25185789

Vancouver

Shi H, Zhang X, Huang L, Wang K, Wang Z. Dual-Band Planar Microwave Solid Complex Dielectric Constant Sensor System Based on E-Interdigital Structure. Sensors. 2025;25(18):5789. doi:10.3390/s25185789

BibTeX
@article{Shi2025,
  author = {Shi, Haoyang and Zhang, Xuchun and Huang, Lin and Wang, Kun and Wang, Zanyang},
  title = {Dual-Band Planar Microwave Solid Complex Dielectric Constant Sensor System Based on E-Interdigital Structure},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {18},
  pages = {5789},
  doi = {10.3390/s25185789}
}
Kostenlos starten →