Fachartikel in der Zeitschrift Entropy, online erschienen am 11.07.2024. Verfasst von Aimin Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610039, China. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Chengdu Science and Technology Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Metro stray currents flowing into transformer-neutral points cause the high neutral DC and a transformer to operate in the DC bias state.Because neutral DC caused by stray current varies with time, the neutral DC value cannot be used as the only characteristic indicator to evaluate the DC bias risk level. Thus, unified characteristic extraction and assessment methods are proposed to evaluate the DC bias risk of a transformer caused by stray current, considering the signals of transformer-neutral DC and vibration. In the characteristic extraction method, the primary characteristics are obtained by comparing the magnitude and frequency distributions of transformer-neutral DC and vibration with and without metro stray current invasion. By analyzing the correlation coefficients, the final characteristics are obtained by clustering the primary characteristics with high correlation. Then, the magnitude and frequency characteristics are extracted and used as indicators to evaluate the DC bias risk. Moreover, to avoid the influence of manual experience on indicator weights, the entropy weight method (EWM) is used to establish the assessment model. Finally, the proposed methods are applied based on the neutral DC and vibration test data of a certain transformer. The results show that the characteristic indicators can be extracted, and the transformer DC bias risk can be evaluated by using the proposed methods.

Schlagwörter

Stichwörter der Autor:innen

characteristic extractionmetrostray currentneutral DCrisk assessmenttransformers DC biasvibration

Autor:innen und Institutionen

  • School of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610039, China.
  • School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China.
  • Shenzhen Power Supply Bureau Co., Ltd., China Southern Power Grid, Shenzhen 518000, China.
  • State Grid Sichuan Electric Power Research Institute, Chengdu 610044, China.

ORCID-Profile: Aimin Wang, Sheng Lin

Förderung

  • National Natural Science Foundation of China
  • Chengdu Science and Technology Project

Zitieren

APA

Wang, A., Lin, S., Wu, G., Li, X., & Wang, T. (2024). Characteristic Extraction and Assessment Methods for Transformers DC Bias Caused by Metro Stray Currents. Entropy, 26(7), 595. https://doi.org/10.3390/e26070595

Vancouver

Wang A, Lin S, Wu G, Li X, Wang T. Characteristic Extraction and Assessment Methods for Transformers DC Bias Caused by Metro Stray Currents. Entropy. 2024;26(7):595. doi:10.3390/e26070595

BibTeX
@article{Wang2024,
  author = {Wang, Aimin and Lin, Sheng and Wu, Guoxing and Li, Xiaopeng and Wang, Tao},
  title = {Characteristic Extraction and Assessment Methods for Transformers DC Bias Caused by Metro Stray Currents},
  journal = {Entropy},
  year = {2024},
  volume = {26},
  number = {7},
  pages = {595},
  doi = {10.3390/e26070595}
}
Kostenlos starten →