EUVIMEDEUVIMED entdecken
Crossref

Probabilistic Evaluation Method of Transformer Neutral Direct Current Distribution in Urban Power Grid Caused by DC Metro Stray Current

Aimin Wang, Sheng Lin, Zhengyou He, Zhang Jingzhuo, Guoxing Wu

IEEE Transactions on Power Delivery · 2023-02 · 38 (1) · 541-552

DOI: 10.1109/tpwrd.2022.3200953 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Power Delivery, 2023-02. Verfasst von Aimin Wang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Sichuan Science and Technology Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the coupling of the DC metro network and urban power grid, the DC metro stray currents flowing into transformers have caused serious DC bias. There is, therefore, a need to evaluate transformer neutral direct currents caused by the DC metro stray current. To achieve this, an evaluation model considering the coupling of DC metro network and urban power grid is proposed. In the modeling principle, metro lines are coupled with grounding grids of transfer stations. The DC metro system and the urban power grid are coupled with the soil and grounding systems. The train operations on DC metro lines are simulated using the Monte Carlo method. And, considering the conditions of one-way conduction devices (OWCDs) and over-voltage protection devices (OVPDs), transformer neutral direct currents are calculated. Moreover, two probability indexes are proposed to evaluate distributions of transformer neutral direct currents. The applicability of the proposed model is verified by comparing the calculation results with test data of the transformer neutral direct current. Using the evaluation model, transformer neutral direct currents are evaluated. The result indicates that substation supplying power to the DC metro network has a large probability of a high-level neutral direct current.

Förderung

  • National Natural Science Foundation of China
  • Sichuan Science and Technology Program

Zitieren

APA

Wang, A., Lin, S., He, Z., Jingzhuo, Z., & Wu, G. (2023). Probabilistic Evaluation Method of Transformer Neutral Direct Current Distribution in Urban Power Grid Caused by DC Metro Stray Current. IEEE Transactions on Power Delivery, 38(1), 541-552. https://doi.org/10.1109/tpwrd.2022.3200953

Vancouver

Wang A, Lin S, He Z, Jingzhuo Z, Wu G. Probabilistic Evaluation Method of Transformer Neutral Direct Current Distribution in Urban Power Grid Caused by DC Metro Stray Current. IEEE Transactions on Power Delivery. 2023;38(1):541-552. doi:10.1109/tpwrd.2022.3200953

BibTeX
@article{Wang2023,
  author = {Wang, Aimin and Lin, Sheng and He, Zhengyou and Jingzhuo, Zhang and Wu, Guoxing},
  title = {Probabilistic Evaluation Method of Transformer Neutral Direct Current Distribution in Urban Power Grid Caused by DC Metro Stray Current},
  journal = {IEEE Transactions on Power Delivery},
  year = {2023},
  volume = {38},
  number = {1},
  pages = {541--552},
  doi = {10.1109/tpwrd.2022.3200953}
}
Kostenlos starten →