EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Biomechanical Comparative Evaluation of the Atrophic Edentulous Mandible Using All-on-4, All-on-5 and All-on-6 Concepts: A Finite Element Analysis

Abhay Datarkar, Neha Ganpat Pawar, Prashant K Pandilwar, Ihsan Caglar Cinar, Eitan Mijiritsky iD

Dentistry Journal · 05.08.2026 · 14 (8) · 480

DOI: 10.3390/dj14080480 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 05.08.2026. Verfasst von Abhay Datarkar und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital Nagpur, Nagpur 440003, Maharashtra, India. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Full-arch implant-supported prostheses, including configurations such as All-on-4, All-on-5, and All-on-6, are widely used for the rehabilitation of the atrophic edentulous mandible; however, their biomechanical performance remains a critical factor for long-term success. Aim/Objectives: To evaluate and compare von Mises stress distribution and deformation patterns among mandibular All-on-4, All-on-5, and All-on-6 configurations using three-dimensional finite element analysis.

Methods

The three-dimensional finite element models of an atrophic edentulous mandible were developed to simulate All-on-4 (Model 1), All-on-5 (Model 2), and All-on-6 (Model 3) implant-supported prostheses under standardized loading conditions (150 N anterior; 300 N posterior bilaterally). Von Mises stress (overall, implant, and bone) and total deformation were assessed. The results were analyzed using descriptive statistics, and a comparative evaluation of von Mises stress and deformation values was performed across the three implant configurations.

Results

Model 2 exhibited the highest overall von Mises stress (76.821 MPa), followed by Model 3 (67.996 MPa) and Model 1 (38.016 MPa). Bone stress was lowest in Model 1 (5.787 MPa) and highest in Model 2 (16.443 MPa). Total deformation was greatest in Model 2 (3.156 × 10−3 mm), whereas Model 3 showed the least deformation (8.2489 × 10−4 mm).

Conclusions

Within the limitations of this study, the All-on-5 configuration demonstrated the highest stress concentration and deformation under the present loading conditions. Increasing implant number does not linearly reduce stress. Among the three evaluated configurations, the modeled All-on-6 configuration demonstrated the lowest deformation under the present loading conditions. Implant positioning and load distribution play a more critical role than implant number alone. The findings are based on a specific finite element model and implant distribution and should not be generalized to all clinical All-on-5 configurations.

Schlagwörter

Stichwörter der Autor:innen

atrophic mandiblebiomechanical evaluationdental implantfinite element analysisstress distribution

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital Nagpur, Nagpur 440003, Maharashtra, India.
  • Department of Oral Implantology, Faculty of Dentistry, Istanbul University, Fatih, Istanbul 34098, Turkey.
  • Department of Head and Neck Surgery and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, School of Dental Medicine, Gray Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv 64239, Israel.

ORCID-Profile: Eitan Mijiritsky

Zitieren

APA

Datarkar, A., Pawar, N. G., Pandilwar, P. K., Cinar, I. C., & Mijiritsky, E. (2026). Biomechanical Comparative Evaluation of the Atrophic Edentulous Mandible Using All-on-4, All-on-5 and All-on-6 Concepts: A Finite Element Analysis. Dentistry Journal, 14(8), 480. https://doi.org/10.3390/dj14080480

Vancouver

Datarkar A, Pawar NG, Pandilwar PK, Cinar IC, Mijiritsky E. Biomechanical Comparative Evaluation of the Atrophic Edentulous Mandible Using All-on-4, All-on-5 and All-on-6 Concepts: A Finite Element Analysis. Dentistry Journal. 2026;14(8):480. doi:10.3390/dj14080480

BibTeX
@article{Datarkar2026,
  author = {Datarkar, Abhay and Pawar, Neha Ganpat and Pandilwar, Prashant K and Cinar, Ihsan Caglar and Mijiritsky, Eitan},
  title = {Biomechanical Comparative Evaluation of the Atrophic Edentulous Mandible Using All-on-4, All-on-5 and All-on-6 Concepts: A Finite Element Analysis},
  journal = {Dentistry Journal},
  year = {2026},
  volume = {14},
  number = {8},
  pages = {480},
  doi = {10.3390/dj14080480}
}
Kostenlos starten →