Evaluation of Fracture Resistance in Teeth with Iatrogenic Perforations Repaired Using the Newly Developed Materials NeoPUTTY and NeoMTA 2: An In Vitro Comparative Study
Dentistry Journal · 14.07.2026 · 14 (7) · 437
DOI: 10.3390/dj14070437 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 14.07.2026. Verfasst von Flora Kakoura und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontology, School of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hellenic Foundation for Research and Innovation.
Abstract (Originalsprache)
Objectives
This study aimed to assess and compare the fracture resistance (FR) of teeth with simulated root perforations repaired using NeoMTA 2, NeoPUTTY, and Biodentine.
Methods
Sixty-five single-rooted human teeth were decoronated to a standardized length of 13 mm from the apex. Their weight, mesiodistal (MD) and buccolingual (BL) dimensions were recorded for even distribution across five groups (n = 13). The teeth in the three experimental groups were instrumented. Standardized 1 mm perforations were created on the buccal root surface at a fixed 105° angle using a precision apparatus. The canals were then obturated with gutta-percha and AH Plus sealer. The perforations were subsequently repaired with NeoMTA 2, NeoPUTTY, or Biodentine. The positive control (PC) group included instrumented and perforated roots, while the negative control (NC) group comprised untreated, intact roots. All control group data used in this study were derived from previously published research. Fracture testing was conducted with a universal testing machine applying a compressive vertical load at 1 mm/min until fracture occurred. The forces were analyzed using one-way analysis of variance (ANOVA), followed by a post hoc Tukey test.
Results
The mean fracture loads were as follows: NC Group: 342.68 ± 146.45 N, PC Group: 212.66 ± 77.89 N, NeoMTA 2 Group: 314.34 ± 131.41 N, NeoPUTTY Group: 243.76 ± 93.71 N, and Biodentine Group: 263.73 ± 94.63 N. No statistically significant differences were observed among experimental groups (p > 0.05).
Conclusions
The three biomaterials showed similar strengthening effects but did not fully restore fracture strength.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Endodontology, School of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
ORCID-Profile: Georgios Mikrogeorgis
Förderung
- Hellenic Foundation for Research and Innovation
Zitieren
APA
Kakoura, F., Lyroudia, K., Economides, N., & Mikrogeorgis, G. (2026). Evaluation of Fracture Resistance in Teeth with Iatrogenic Perforations Repaired Using the Newly Developed Materials NeoPUTTY and NeoMTA 2: An In Vitro Comparative Study. Dentistry Journal, 14(7), 437. https://doi.org/10.3390/dj14070437
Vancouver
Kakoura F, Lyroudia K, Economides N, Mikrogeorgis G. Evaluation of Fracture Resistance in Teeth with Iatrogenic Perforations Repaired Using the Newly Developed Materials NeoPUTTY and NeoMTA 2: An In Vitro Comparative Study. Dentistry Journal. 2026;14(7):437. doi:10.3390/dj14070437
BibTeX
@article{Kakoura2026,
author = {Kakoura, Flora and Lyroudia, Kleoniki and Economides, Nikolaos and Mikrogeorgis, Georgios},
title = {Evaluation of Fracture Resistance in Teeth with Iatrogenic Perforations Repaired Using the Newly Developed Materials NeoPUTTY and NeoMTA 2: An In Vitro Comparative Study},
journal = {Dentistry Journal},
year = {2026},
volume = {14},
number = {7},
pages = {437},
doi = {10.3390/dj14070437}
}
EUVIMED