Standardization and Validation of Digital Volumetric Measurement Methods for Alveolar Cleft Defects Using 3D Imaging
Dentistry Journal · 23.04.2026 · 14 (5) · 247
DOI: 10.3390/dj14050247 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 23.04.2026. Verfasst von Inka Saraswati und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Universitas Indonesia, Salemba Raya No. 4, Central Jakarta 10430, Indonesia. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Indonesia, Universitas Indonesia.
Abstract (Originalsprache)
Background/Objectives: Accurate quantification of alveolar cleft defects for bone grafting remains difficult due to inconsistent anatomical boundaries. This study established an expert consensus on boundary landmarks for alveolar bone graft (ABG) planning and validated the accuracy and reliability of digital volumetric measurement methods.
Methods
Three cleft specialists performed repeated simulated graft procedures in seven patient-specific 3D-printed models, first according to the operator’s clinical judgment, and subsequently according to panel-derived consensus boundaries. Two radiologists independently conducted digital volumetric assessments in 3D X-ray imaging using four measurement approaches (axial tracing, interpolated axial tracing, landmark-based mirroring, and mesh-based mirroring), generating 56 independent digital segmentations to be evaluated against the consensus-based physical reference standard. Volumes of the defects were recorded, intra- and inter-rater reliabilities were calculated using the intraclass correlation coefficient (ICC), and differences among methods were analyzed.
Results
Operator-defined plans showed significant inter-operator differences (p < 0.001) with poor-to-excellent reliability (intra-rater ICC 0.060–0.967; inter-rater ICC 0.300–0.635). Consensus established standardized boundaries: tilted plane from base of anterior nasal spine to hard palate, cemento-enamel junctions, incisive canal, and alveolar contour. Consensus-based filling showed non-significant inter-rater differences (p = 0.139) and substantially improved reliability (intra-rater ICC 0.904–0.988; inter-rater ICC 0.622–0.861). Among the four digital methods evaluated, axial tracing demonstrated excellent reliability (intra-rater ICC 0.971–0.99; inter-rater ICC 0.965) and high accuracy (mean difference 0.001–0.026 cm3), with no significant difference (p = 0.999) from the physical reference standard.
Conclusions
These proposed consensus-based boundary definitions and validated volumetric measurement methods improved the accuracy and reproducibility of personalized alveolar bone graft planning.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Universitas Indonesia, Salemba Raya No. 4, Central Jakarta 10430, Indonesia.
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Universitas Indonesia, Salemba Raya No. 4, Central Jakarta 10430, Indonesia.
- Department of Orthodontics, Faculty of Dentistry, Universitas Indonesia, Salemba Raya No. 4, Central Jakarta 10430, Indonesia.
- Department of Oral and Maxillofacial Surgery, Graduate School of Dental and Medical Sciences, Kagoshima University, 8-35-1, Sakuragaoka, Kagoshima 890-8544, Japan.
- Cleft Center, Harapan Kita Children and Mother Hospital, Letnan Jenderal S Parman Kavling. 87, West Jakarta 11420, Indonesia.
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Universitas Padjajaran, Jatinangor 45363, Indonesia.
ORCID-Profile: Dwi Ariawan, Sariesendy Sumardi, Bramma Kiswanjaya, Bayu Trinanda Putra, Hanna H Bachtiar-Iskandar, Takeshi Mitsuyasu
Förderung
- University of Indonesia
- Universitas Indonesia
Zitieren
APA
Saraswati, I., Priaminiarti, M., Ariawan, D., Sumardi, S., Kiswanjaya, B., Putra, B. T., Bachtiar-Iskandar, H. H., Nakamura, N., Hak, M. S., Suhartanto, H., & Mitsuyasu, T. (2026). Standardization and Validation of Digital Volumetric Measurement Methods for Alveolar Cleft Defects Using 3D Imaging. Dentistry Journal, 14(5), 247. https://doi.org/10.3390/dj14050247
Vancouver
Saraswati I, Priaminiarti M, Ariawan D, Sumardi S, Kiswanjaya B, Putra BT, et al. Standardization and Validation of Digital Volumetric Measurement Methods for Alveolar Cleft Defects Using 3D Imaging. Dentistry Journal. 2026;14(5):247. doi:10.3390/dj14050247
BibTeX
@article{Saraswati2026,
author = {Saraswati, Inka and Priaminiarti, Menik and Ariawan, Dwi and Sumardi, Sariesendy and Kiswanjaya, Bramma and Putra, Bayu Trinanda and Bachtiar-Iskandar, Hanna H and Nakamura, Norifumi and Hak, Muhammad Syafrudin and Suhartanto, Heru and Mitsuyasu, Takeshi},
title = {Standardization and Validation of Digital Volumetric Measurement Methods for Alveolar Cleft Defects Using 3D Imaging},
journal = {Dentistry Journal},
year = {2026},
volume = {14},
number = {5},
pages = {247},
doi = {10.3390/dj14050247}
}