Validation of a portable three-dimensional imaging system for volumetric measurement in the periorbital region
Frontiers in Medicine · 08.08.2025 · 12
DOI: 10.3389/fmed.2025.1647489 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Medicine, online erschienen am 08.08.2025. Verfasst von Xuan Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, Zhejiang Provincial Key Laboratory of Ophthalmology, Zhejiang …. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
To evaluate the reliability and accuracy of a portable structured light-based three-dimensional (3D) imaging system for volumetric measurement in the periorbital region.
Methods
Five hemispherical 3D printed resin models with different sizes and colors, including the flesh-colored models with 6 (Model 1), 4 (Model 2), and 2 (Model 3) mm in diameter, and the black (Model 4) and gray (Model 5) models with 6 mm in diameter, were affixed to the lower eyelid or upper eyelid of 40 volunteers. One researcher used the portable 3D imaging system to collect the 3D images and two raters measured the volume of the models on images. Intra-device, intra-rater and inter-rater reliabilities and accuracy of the volumetric measurement were evaluated by intraclass correlation coefficient (ICC), mean absolute difference (MAD), technical error of measurement (TEM), relative error measurement (REM), and relative TEM (rTEM).
Results
The intra-device reliability of the 3D imaging system for volumetric measurement in the periorbital region was excellent (ICC = 0.922, MAD = 0.11 mm 3 , TEM = 0.09 mm 3 , REM = 0.19%, rTEM = 0.15%). The intra-rater reliability for volumetric measurement of the Model 1 on the lower eyelid was the highest (ICC = 0.953, MAD = 0.08 mm 3 , TEM = 0.06 mm 3 , REM = 0.13%, rTEM = 0.11%). The inter-rater reliability for volumetric measurement of the Model 1 on the lower eyelid was the highest (ICC = 0.889, MAD = 0.14 mm 3 , TEM = 0.11 mm 3 , REM = 0.24%, rTEM = 0.19%). The accuracy for volumetric measurement of the Model 1 on the lower eyelid was the highest (MAD = 0.24 mm 3 , REM = 0.43%).
Conclusion
The portable 3D imaging system proved to measure the volumes of periorbital flesh-colored objects reliably and accurately. This finding demonstrated that this device has great potential for diagnosis, post-operative evaluation, and long-term follow-up of volumetric changes in oculoplastics.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, Zhejiang Provincial Key Laboratory of Ophthalmology, Zhejiang Provincial Clinical Research Center for Eye Diseases, Zhejiang Provinc…
Zitieren
APA
Zhang, X., Shao, J., Dai, N., Li, H., Guo, Y., Ye, J., & Lou, L. (2025). Validation of a portable three-dimensional imaging system for volumetric measurement in the periorbital region. Frontiers in Medicine, 12. https://doi.org/10.3389/fmed.2025.1647489
Vancouver
Zhang X, Shao J, Dai N, Li H, Guo Y, Ye J, et al. Validation of a portable three-dimensional imaging system for volumetric measurement in the periorbital region. Frontiers in Medicine. 2025;12. doi:10.3389/fmed.2025.1647489
BibTeX
@article{Zhang2025,
author = {Zhang, Xuan and Shao, Ji and Dai, Ningxin and Li, Huimin and Guo, Yongwei and Ye, Juan and Lou, Lixia},
title = {Validation of a portable three-dimensional imaging system for volumetric measurement in the periorbital region},
journal = {Frontiers in Medicine},
year = {2025},
volume = {12},
doi = {10.3389/fmed.2025.1647489}
}