EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Occlusal Adjustment in Free‐End Implant‐Supported Restorations: Digital Scans Versus Conventional Impressions With Full‐ and Half‐Arch Techniques

Mohammadreza Nakhaei, Hossein Dashti, Arsalan Shahri iD, Mahsa Rahmani, Ali Kazemian, Saeid Sabzevari, Masih Rezaee iD

Clinical and Experimental Dental Research · 2026-10 · 12 (5)

DOI: 10.1002/cre2.70454 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical and Experimental Dental Research, online erschienen am 17.09.2026. Verfasst von Mohammadreza Nakhaei und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran. Hauptthemen laut MEDLINE: Dental Prosthesis, Implant-Supported, Dental Impression Technique, Occlusal Adjustment, Crowns. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mashhad University of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To quantify the occlusal adjustment required for two‐unit, implant‐supported polymethyl‐methacrylate (PMMA) crowns with either digital or conventional impression techniques, using full‐arch and half‐arch workflows. Material and Methods An acrylic maxillary–mandibular model carrying two bone‐level implant analogs (sites 46–47) was mounted on a semi‐adjustable articulator. Twenty impressions were made ( n = 5 per group): digital full‐arch, digital half‐arch, conventional full‐arch, and conventional half‐arch. PMMA crowns were designed using computer‐aided design (CAD) software, milled, and surface‐scanned before adjustment. Occlusal contacts were refined on the articulator with 21 µm film while recording adjustment time. Pre‐ and post‐adjustment scans were superimposed and analyzed using three‐dimensional surface analysis software to quantify mean material reduction (µm). Data were analyzed with one‐way ANOVA and independent‐samples t ‐tests ( α = 0.05).

Results

Digital workflows required significantly less occlusal reduction (146 ± 35 µm vs. 226 ± 35 µm; p = 0.035) and shorter adjustment times (144 ± 36 s vs. 385 ± 36 s; p < 0.001) than conventional, with no effect of arch span (full vs. half; p > 0.05). Within protocols, the digital half‐arch group showed the smallest adjustment (127 ± 37 µm) and fastest finishing (98 ± 33 s), whereas the conventional half‐arch group required the longest time (456 ± 21 s).

Conclusion

Fully digital impressions reduce both the amount of occlusal adjustment and the chairside time needed to seat implant‐supported crowns compared with conventional silicone impressions. Reducing the scan to a half‐arch does not compromise occlusal precision, making the digital half‐arch workflow an efficient alternative for posterior, free‐end implant restorations. Clinical Relevance In implant posterior PMMA crowns, the impact of impression/workflow choice on occlusal adjustment is unclear. This in‐vitro study measured occlusal reduction and chairside time across digital versus conventional and full‐ versus half‐arch workflows. Digital, especially half‐arch, required less adjustment and shorter time. Clinically, a digital half‐arch approach may streamline delivery and reduce unnecessary material removal, pending confirmation in patient‐based settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Prosthesis, Implant-SupportedDental Impression TechniqueOcclusal AdjustmentCrownsComputer-Aided DesignHumansPolymethyl MethacrylateDental Prosthesis DesignDental Impression Materials

Stichwörter der Autor:innen

CAD‐CAMdental impression techniquesdigital impressionintraoral scannersocclusal adjustment

Substanzen

Polymethyl MethacrylateDental Impression Materials

Autor:innen und Institutionen

  • Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Dental Materials Research Center, Mashhad Dental School, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Department of Prosthodontics, School of Dentistry, Bojnurd University of Medical Sciences, Bojnord, Iran.
  • Department of Community Oral Health, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.

ORCID-Profile: Arsalan Shahri, Masih Rezaee

Förderung

  • Mashhad University of Medical Sciences

Zitieren

APA

Nakhaei, M., Dashti, H., Shahri, A., Rahmani, M., Kazemian, A., Sabzevari, S., & Rezaee, M. (2026). Occlusal Adjustment in Free‐End Implant‐Supported Restorations: Digital Scans Versus Conventional Impressions With Full‐ and Half‐Arch Techniques. Clinical and Experimental Dental Research, 12(5). https://doi.org/10.1002/cre2.70454

Vancouver

Nakhaei M, Dashti H, Shahri A, Rahmani M, Kazemian A, Sabzevari S, et al. Occlusal Adjustment in Free‐End Implant‐Supported Restorations: Digital Scans Versus Conventional Impressions With Full‐ and Half‐Arch Techniques. Clinical and Experimental Dental Research. 2026;12(5). doi:10.1002/cre2.70454

BibTeX
@article{Nakhaei2026,
  author = {Nakhaei, Mohammadreza and Dashti, Hossein and Shahri, Arsalan and Rahmani, Mahsa and Kazemian, Ali and Sabzevari, Saeid and Rezaee, Masih},
  title = {Occlusal Adjustment in Free‐End Implant‐Supported Restorations: Digital Scans Versus Conventional Impressions With Full‐ and Half‐Arch Techniques},
  journal = {Clinical and Experimental Dental Research},
  year = {2026},
  volume = {12},
  number = {5},
  doi = {10.1002/cre2.70454}
}
Kostenlos starten →