EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Unsupervised Metal Artifact Reduction in Dental CBCT Using Fine-Tuned Cycle-Consistent Adversarial Networks

Thamindu Chamika, Sithum N. A. Dhanapala, Sasindu Nimalaweera, Maheshi B. Dissanayake, Ruwan D. Jayasinghe

Digital · 17.04.2026 · 6 (2) · 31

DOI: 10.3390/digital6020031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Digital, online erschienen am 17.04.2026. Verfasst von Thamindu Chamika und 4 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Metal artifacts generated by dental implants significantly degrade cone-beam computed tomography (CBCT) volumes, obscuring critical anatomical structures and compromising diagnostic precision. To address this, an unsupervised deep learning framework has been proposed for Metal Artifact Reduction (MAR) utilizing a Cycle-Consistent Adversarial Network (CycleGAN) optimized for high-fidelity restoration. Unlike supervised methods that rely on unattainable voxel-aligned paired datasets, the proposed approach leverages an unpaired dataset of approximately 4000 images, curated from the public ToothFairy dataset. The architecture integrates U-Net-based generators and PatchGAN discriminators, specifically tuned to mitigate generative hallucinations and preserve morphological integrity. Quantitative benchmarking on a held-out test set demonstrates a 34.6% improvement in the Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE) score, a substantial reduction in Fréchet Inception Distance (FID) from 207.03 to 157.04, and a superior Structural Similarity Index Measure (SSIM) of 0.9105. The framework achieves real-time efficiency with a 3.03 ms inference time per slice, effectively suppressing artifacts while preserving anatomical detail. Expert validation confirms high fidelity; however, to ensure reliability in extreme cases, the architecture is recommended as a clinical decision-support tool under human-in-the-loop oversight. By enhancing diagnostic clarity via a scalable software pipeline, this study provides a robust solution for high-fidelity dental implant imaging.

Zitieren

APA

Chamika, T., Dhanapala, S. N. A., Nimalaweera, S., Dissanayake, M. B., & Jayasinghe, R. D. (2026). Unsupervised Metal Artifact Reduction in Dental CBCT Using Fine-Tuned Cycle-Consistent Adversarial Networks. Digital, 6(2), 31. https://doi.org/10.3390/digital6020031

Vancouver

Chamika T, Dhanapala SNA, Nimalaweera S, Dissanayake MB, Jayasinghe RD. Unsupervised Metal Artifact Reduction in Dental CBCT Using Fine-Tuned Cycle-Consistent Adversarial Networks. Digital. 2026;6(2):31. doi:10.3390/digital6020031

BibTeX
@article{Chamika2026,
  author = {Chamika, Thamindu and Dhanapala, Sithum N. A. and Nimalaweera, Sasindu and Dissanayake, Maheshi B. and Jayasinghe, Ruwan D.},
  title = {Unsupervised Metal Artifact Reduction in Dental CBCT Using Fine-Tuned Cycle-Consistent Adversarial Networks},
  journal = {Digital},
  year = {2026},
  volume = {6},
  number = {2},
  pages = {31},
  doi = {10.3390/digital6020031}
}
Kostenlos starten →