Coupled Diffusion Models for Metal Artifact Reduction of Clinical Dental CBCT Images
IEEE Transactions on Medical Imaging · 2025-12 · 44 (12) · 5103-5116
DOI: 10.1109/tmi.2025.3587131 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2025-12. Verfasst von Zhouzhuo Zhang und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Artifacts, Cone-Beam Computed Tomography, Metals, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: National Natural Science Foundation of China, China Ministry of Science and Technology, STI2030-Major Projects.
Abstract (Originalsprache)
Metal dental implants may introduce metal artifacts (MA) during the CBCT imaging process, causing significant interference in subsequent diagnosis. In recent years, many deep learning methods for metal artifact reduction (MAR) have been proposed. Due to the huge difference between synthetic and clinical MA, supervised learning MAR methods may perform poorly in clinical settings. Many existing unsupervised MAR methods trained on clinical data often suffer from incorrect dental morphology. To alleviate the above problems, in this paper, we propose a new MAR method of Coupled Diffusion Models (CDM) for clinical dental CBCT images. Specifically, we separately train two diffusion models on clinical MA-degraded images and clinical clean images to obtain prior information, respectively. During the denoising process, the variances of noise levels are calculated from MA images and the prior of diffusion models. Then we develop a noise transformation module between the two diffusion models to transform the MA noise image into a new initial value for the denoising process. Our designs effectively exploit the inherent transformation between the misaligned MA-degraded images and clean images. Additionally, we introduce an MA-adaptive inference technique to better accommodate the MA degradation in different areas of an MA-degraded image. Experiments on our clinical dataset demonstrate that our CDM outperforms the comparison methods on both objective metrics and visual quality, especially for severe MA degradation. We will publicly release our code.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- National Natural Science Foundation of China
- China Ministry of Science and Technology
- STI2030-Major Projects
- Shanghai Municipal Central Guided Local Science and Technology Development Fund
- Key Research and Development Program of Guangdong Province, China
- High performance computing (HPC) Platform of ShanghaiTech University
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Zhang, Z., Yan, J., Shi, Y., Cui, Z., Xu, J., & Shen, D. (2025). Coupled Diffusion Models for Metal Artifact Reduction of Clinical Dental CBCT Images. IEEE Transactions on Medical Imaging, 44(12), 5103-5116. https://doi.org/10.1109/tmi.2025.3587131
Vancouver
Zhang Z, Yan J, Shi Y, Cui Z, Xu J, Shen D. Coupled Diffusion Models for Metal Artifact Reduction of Clinical Dental CBCT Images. IEEE Transactions on Medical Imaging. 2025;44(12):5103-5116. doi:10.1109/tmi.2025.3587131
BibTeX
@article{Zhang2025,
author = {Zhang, Zhouzhuo and Yan, Juncheng and Shi, Yuxuan and Cui, Zhiming and Xu, Jun and Shen, Dinggang},
title = {Coupled Diffusion Models for Metal Artifact Reduction of Clinical Dental CBCT Images},
journal = {IEEE Transactions on Medical Imaging},
year = {2025},
volume = {44},
number = {12},
pages = {5103--5116},
doi = {10.1109/tmi.2025.3587131}
}
EUVIMED