EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Diagnostic Efficiency of Sequential Tissue Acquisition During Shape-Sensing Robotic-Assisted Bronchoscopy in a Thoracic Surgery Setting: A Biopsy-Level Analysis

Hruy Menghesha, Philipp Feodorovici, Joachim Schmidt, Donatas Zalepugas

Diagnostics · 20.11.2026 · 16 (22) · 3902

DOI: 10.3390/diagnostics16223902 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 20.11.2026. Verfasst von Hruy Menghesha und 3 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Economic Affairs, Industry, Climate Action, Energy of the State of North Rhine-Westphalia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Shape-sensing robotic-assisted bronchoscopy (ssRAB) enables precise navigation to peripheral pulmonary lesions, while intraprocedural imaging can improve assessment of biopsy tool positioning relative to the target. However, successful lesion localization does not necessarily translate into diagnostic tissue acquisition, and little is known about the diagnostic contribution of individual sequential biopsy specimens. This study aimed to evaluate the diagnostic yield and sequential tissue acquisition during ssRAB at both the lesion and individual specimen level, with particular emphasis on the number of biopsies required to establish a diagnosis.

Methods

We performed a retrospective single-center analysis of consecutive thoracic surgical ssRAB procedures using the ION™ Endoluminal System (Intuitive Surgical, Sunnyvale, CA, USA) between August 2024 and March 2026. Procedures performed exclusively for bronchoscopic lesion marking without diagnostic tissue acquisition were excluded. Intraprocedural imaging was performed using cone-beam computed tomography (CBCT) or C-arm fluoroscopy. Primary outcome measures included specimen-level diagnostic yield, lesion-level diagnostic yield, the biopsy number at which the first diagnostic specimen was obtained, and the diagnostic-to-total specimen ratio per lesion.

Results

Eighty-four patients with 118 pulmonary nodules were included. Median lesion diameter was 9.0 mm, and 94 lesions (79.7%) were solid, 10 (8.5%) were subsolid, and 14 (11.9%) were pure ground-glass opacities. CBCT was used in 111 lesions (94.1%) and C-arm fluoroscopy in seven (5.9%). A diagnostic bronchoscopic result was obtained in 101 lesions, corresponding to a lesion-level diagnostic yield of 85.6%. A total of 794 individual biopsy specimens were obtained, of which 487 (61.3%) were diagnostic. The mean diagnostic-to-total specimen ratio per lesion was 0.59 ± 0.39. Among diagnostically successful lesions, the first biopsy specimen was diagnostic in 68/101 cases (67.3%). A diagnosis was established within the first three biopsy specimens in 91/101 lesions (90.1%) and within the first five specimens in 99/101 lesions (98.0%). In two lesions, the first diagnostic specimen was obtained with the eighth biopsy.

Conclusions

Although ssRAB achieved a high lesion-level diagnostic yield, diagnostic performance at the individual specimen level was substantially lower. Most successful diagnoses were established within the first three biopsy specimens, while additional sampling continued to provide incremental diagnostic information. These findings highlight the distinction between successful lesion localization and successful tissue acquisition and support a sequential, rather than single-sample, approach to tissue acquisition during ssRAB.

Förderung

  • Ministry of Economic Affairs, Industry, Climate Action
  • Energy of the State of North Rhine-Westphalia

Zitieren

APA

Menghesha, H., Feodorovici, P., Schmidt, J., & Zalepugas, D. (2026). Diagnostic Efficiency of Sequential Tissue Acquisition During Shape-Sensing Robotic-Assisted Bronchoscopy in a Thoracic Surgery Setting: A Biopsy-Level Analysis. Diagnostics, 16(22), 3902. https://doi.org/10.3390/diagnostics16223902

Vancouver

Menghesha H, Feodorovici P, Schmidt J, Zalepugas D. Diagnostic Efficiency of Sequential Tissue Acquisition During Shape-Sensing Robotic-Assisted Bronchoscopy in a Thoracic Surgery Setting: A Biopsy-Level Analysis. Diagnostics. 2026;16(22):3902. doi:10.3390/diagnostics16223902

BibTeX
@article{Menghesha2026,
  author = {Menghesha, Hruy and Feodorovici, Philipp and Schmidt, Joachim and Zalepugas, Donatas},
  title = {Diagnostic Efficiency of Sequential Tissue Acquisition During Shape-Sensing Robotic-Assisted Bronchoscopy in a Thoracic Surgery Setting: A Biopsy-Level Analysis},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {3902},
  doi = {10.3390/diagnostics16223902}
}
Kostenlos starten →