Fachartikel in der Zeitschrift Diagnostics, online erschienen am 31.10.2026. Verfasst von Jiandong Guo und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Shenzhen Hospital (Futian) of Guangzhou University of Chinese Medicine, 6001 Beihuan Avenue, Futian District, Shenzhen 51800…. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, 2024 Medical and Health Science and Technology Program of Longgang District, 2024 In-house Scientific Research Talent Training Program (Category B) of Shenzhen Longgang Central Hospital.
Abstract (Originalsprache)
Background/Objectives: Conventional cervical magnetic resonance imaging (MRI) depicts cortical bone poorly, whereas computed tomography (CT) adds radiation exposure. We evaluated whether adding zero-echo-time (ZTE) imaging improves detection of CT-defined grade ≥2 foraminal stenosis.
Methods
This single-centre retrospective diagnostic accuracy study included 81 consecutive eligible patients evaluated between October 2024 and June 2025 who underwent cervical MRI and CT within 14 days. Two blinded musculoskeletal radiologists graded 810 foramina from C2-C3 through C6-C7 using conventional MRI and MRI + ZTE. A study-specific scale incorporated narrowing, nerve-root morphology, and surrounding fat appearances. Consensus CT grading was the reference standard; grade ≥2 defined a positive foramen. Paired differences were assessed with patient-clustered bootstrap resampling.
Results
Mean age was 48.9 ± 13.6 years; 55 patients were women. CT identified grade ≥2 stenosis in 150/810 foramina (18.5%). Adding ZTE increased sensitivity from 68.7% to 87.3% for Reader 1 and from 17.3% to 35.3% for Reader 2. Sensitivity differences were 18.7 percentage points (95% confidence interval [CI], 10.6–27.1) and 18.0 percentage points (95% CI, 6.6–30.3), respectively. Specificity increased from 90.5% to 96.8% and from 96.7% to 97.6%, respectively. Areas under the receiver operating characteristic curve increased by 0.115 (95% CI, 0.076–0.164) and 0.121 (95% CI, 0.061–0.184). Binary interreader agreement increased numerically from κ = 0.25 to κ = 0.41.
Conclusions
Adding ZTE improved detection of CT-defined grade ≥2 foraminal stenosis, although sensitivity remained low for one reader. Effects on CT use, management decisions, and clinical outcomes require prospective evaluation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Shenzhen Hospital (Futian) of Guangzhou University of Chinese Medicine, 6001 Beihuan Avenue, Futian District, Shenzhen 518000, China.
- Laboratory of Molecular Imaging and Medical Intelligence, Department of Radiology, Longgang Central Hospital of Shenzhen; Shenzhen Clinical Medical College, Guangzhou University of Chinese Medicine; Longgang Clinical In…
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 334 Jungong Road, Yangpu District, Shanghai 200093, China.
ORCID-Profile: Gan Cao
Förderung
- National Natural Science Foundation of China
- 2024 Medical and Health Science and Technology Program of Longgang District
- 2024 In-house Scientific Research Talent Training Program (Category B) of Shenzhen Longgang Central Hospital
- Shenzhen Longgang Central Hospital
Zitieren
APA
Guo, J., Zeng, S., Tang, W., Zhang, T., Zhuang, S., Zhu, J., Xiao, P., Li, Y., Li, W., Xu, S., & Cao, G. (2026). Incremental Diagnostic Value of Zero-Echo-Time Magnetic Resonance Imaging for Osseous Cervical Neural Foraminal Stenosis: A Retrospective Multireader Study. Diagnostics, 16(21), 3597. https://doi.org/10.3390/diagnostics16213597
Vancouver
Guo J, Zeng S, Tang W, Zhang T, Zhuang S, Zhu J, et al. Incremental Diagnostic Value of Zero-Echo-Time Magnetic Resonance Imaging for Osseous Cervical Neural Foraminal Stenosis: A Retrospective Multireader Study. Diagnostics. 2026;16(21):3597. doi:10.3390/diagnostics16213597
BibTeX
@article{Guo2026,
author = {Guo, Jiandong and Zeng, Shasha and Tang, Wenke and Zhang, Tiejun and Zhuang, Shilong and Zhu, Jichao and Xiao, Ping and Li, Yafen and Li, Wenxin and Xu, Song and Cao, Gan},
title = {Incremental Diagnostic Value of Zero-Echo-Time Magnetic Resonance Imaging for Osseous Cervical Neural Foraminal Stenosis: A Retrospective Multireader Study},