EUVIMEDEUVIMED entdecken
Crossref

MR-based evaluation of osseous cervical neural foraminal stenosis (OCNFS) using fast-field-echo resembling CT using restricted echo-spacing (FRACTURE)

Dejun She, Dongmei Jiang, Junhuan Hong, Yuwei Pan, Xiang Lin, Weilin Huang, Xiaojun Lin, Peiying You, Xiance Zhao, Ruiquan Chen, Dairong Cao

European Spine Journal · 2026-04 · 35 (4) · 1762-1770

DOI: 10.1007/s00586-025-09112-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Spine Journal, online erschienen am 17.07.2025. Verfasst von Dejun She und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, First Affiliated Hospital of Fujian Medical University, Fuzhou, China. Hauptthemen laut MEDLINE: Cervical Vertebrae, Tomography, X-Ray Computed, Spinal Stenosis, Radiculopathy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Fujian Provincial Finance Department.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aimed to assess the feasibility of fast-field-echo resembling CT using restricted echo-spacing (FRACTURE) for evaluating osseous cervical neural foraminal stenosis (OCNFS). METHODS: A total of 280 cervical foramina from 28 patients with cervical radiculopathy (CR) were analyzed on oblique sagittal CT, FRACTURE, T1WI, and T2WI from bilateral C2/3 to C6/7 segments by three readers. CT served as the reference standard to identify OCNFS. Detection rate and grade of OCNFS were assessed. OCNFS severity was classified into four grades according to Park's system: Grade 0 (no stenosis), Grade 1 (mild stenosis), Grade 2 (moderate stenosis), and Grade 3 (severe stenosis). Inter-modality agreements of OCNFS grade were evaluated using linear weighted Cohen's kappa (κ). Sensitivity and specificity were calculated to compare diagnostic performance between FRACTURE and conventional MRI for the diagnosis of OCNFS. RESULTS: The inter-modality agreement of OCNFS grade was substantial between CT and FRACTURE (κ = 0.689-0.715), and moderate between CT and T1WI (κ = 0.427-0.594) or T2WI (κ = 0.462-0.604). Among the 280 cervical neural foramina, 104 were diagnosed as OCNFS using CT. Detection rate of OCNFS was 96.15% (100/104) for FRACTURE, 76.92% (80/104) for T1WI, and 95.19% (99/104) for T2WI. FRACTURE achieved a sensitivity of 96.2% and a specificity of 97.2% for detecting OCNFS. T1WI demonstrated a sensitivity of 76.9% and a specificity of 85.2%, while T2WI exhibited a sensitivity of 95.2% and a specificity of 73.9% for detecting OCNFS. CONCLUSION: FRACTURE can provide a reliable alternative to CT for evaluating OCNFS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cervical VertebraeTomography, X-Ray ComputedSpinal StenosisRadiculopathyMagnetic Resonance ImagingHumansFemaleMaleMiddle AgedAgedAdultSensitivity and SpecificityFeasibility StudiesAged, 80 and over

Stichwörter der Autor:innen

Cervical radiculopathyDiagnostic accuracyMagnetic resonance bone imagingOsseous cervical foraminal stenosis

Autor:innen und Institutionen

  • Department of Radiology, First Affiliated Hospital of Fujian Medical University, Fuzhou, China.
  • Department of Radiology, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, China.
  • Philips (China), Shanghai, China.
  • Department of Radiology, First Affiliated Hospital of Fujian Medical University, Fuzhou, China. 10659086@qq.com.
  • Department of Radiology, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, China. 10659086@qq.com.
  • Department of Radiology, First Affiliated Hospital of Fujian Medical University, Fuzhou, China. dairongcao@163.com.

Förderung

  • Fujian Provincial Finance Department

Zitieren

APA

She, D., Jiang, D., Hong, J., Pan, Y., Lin, X., Huang, W., Lin, X., You, P., Zhao, X., Chen, R., & Cao, D. (2026). MR-based evaluation of osseous cervical neural foraminal stenosis (OCNFS) using fast-field-echo resembling CT using restricted echo-spacing (FRACTURE). European Spine Journal, 35(4), 1762-1770. https://doi.org/10.1007/s00586-025-09112-4

Vancouver

She D, Jiang D, Hong J, Pan Y, Lin X, Huang W, et al. MR-based evaluation of osseous cervical neural foraminal stenosis (OCNFS) using fast-field-echo resembling CT using restricted echo-spacing (FRACTURE). European Spine Journal. 2026;35(4):1762-1770. doi:10.1007/s00586-025-09112-4

BibTeX
@article{She2026,
  author = {She, Dejun and Jiang, Dongmei and Hong, Junhuan and Pan, Yuwei and Lin, Xiang and Huang, Weilin and Lin, Xiaojun and You, Peiying and Zhao, Xiance and Chen, Ruiquan and Cao, Dairong},
  title = {MR-based evaluation of osseous cervical neural foraminal stenosis (OCNFS) using fast-field-echo resembling CT using restricted echo-spacing (FRACTURE)},
  journal = {European Spine Journal},
  year = {2026},
  volume = {35},
  number = {4},
  pages = {1762--1770},
  doi = {10.1007/s00586-025-09112-4}
}
Kostenlos starten →