Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma
Diagnostics · 27.10.2026 · 16 (21) · 3528
DOI: 10.3390/diagnostics16213528 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 27.10.2026. Verfasst von Murshidah Hassan Basri und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, …. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
We aimed to evaluate the agreement, test–retest reliability, test duration, and patient acceptability of Melbourne Rapid Fields (MRF) tablet perimetry compared with Humphrey Field Analyzer (HFA) 24-2 SITA-Standard perimetry in glaucoma patients.
Methods
This cross-sectional study evaluated 64 eyes of 64 patients with primary or secondary glaucoma. Participants underwent both HFA and MRF perimetry in a non-randomized sequence. Agreement was analyzed using intraclass correlation coefficients (ICC) and Bland–Altman analysis. Test–retest reliability of MRF was evaluated in 47 participants after 4 weeks. Acceptability was assessed via questionnaires.
Results
MRF demonstrated comparable reliability indices to HFA (p > 0.05), although these findings do not establish equivalent clinical reliability due to differences in platform-specific definitions. MRF demonstrated excellent test–retest reliability for MD (ICC 0.993), PD (ICC 0.992), and VC (ICC 0.992; all p < 0.001). Compared with HFA, MRF produced significantly less negative MD (−6.27 ± 5.55 vs. −8.32 ± 5.47 dB, p < 0.001) and higher PSD/PD (7.48 ± 3.26 vs. 6.33 ± 4.11 dB, p < 0.001), while VFI/VC did not differ significantly (p = 0.808). Overall agreement was good-to-excellent MD (ICC 0.949), PSD/PD (ICC 0.880), and VFI/VC (ICC 0.930). However, exploratory severity-stratified Bland–Altman analysis suggested greater variability in moderate and severe glaucoma. MRF was significantly faster than HFA (4.22 ± 0.81 vs. 5.46 ± 1.33 min, p < 0.001). All patients reported it was easy and comfortable.
Conclusions
MRF provides excellent test–retest reliability, shorter testing duration, and high patient acceptability. While overall agreement is high, systematic differences and greater advanced-stage variability prevent direct interchangeability with HFA. Instead, MRF serves as a practical, complementary platform for accessible, frequent testing.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, Malaysia.
- Department of Ophthalmology, Hospital Canselor Tuanku Muhriz, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, Malaysia.
Zitieren
APA
Basri, M. H., Cheng, T. C., Nasaruddin, R. A., & Hamzah, J. C. (2026). Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma. Diagnostics, 16(21), 3528. https://doi.org/10.3390/diagnostics16213528
Vancouver
Basri MH, Cheng TC, Nasaruddin RA, Hamzah JC. Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma. Diagnostics. 2026;16(21):3528. doi:10.3390/diagnostics16213528
BibTeX
@article{Basri2026,
author = {Basri, Murshidah Hassan and Cheng, Teck Chee and Nasaruddin, Rona Asnida and Hamzah, Jemaima Che},
title = {Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {21},
pages = {3528},
doi = {10.3390/diagnostics16213528}
}
EUVIMED