EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma

Murshidah Hassan Basri, Teck Chee Cheng, Rona Asnida Nasaruddin, Jemaima Che Hamzah

Diagnostics · 27.10.2026 · 16 (21) · 3528

DOI: 10.3390/diagnostics16213528 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 27.10.2026. Verfasst von Murshidah Hassan Basri und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, …. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

We aimed to evaluate the agreement, test–retest reliability, test duration, and patient acceptability of Melbourne Rapid Fields (MRF) tablet perimetry compared with Humphrey Field Analyzer (HFA) 24-2 SITA-Standard perimetry in glaucoma patients.

Methods

This cross-sectional study evaluated 64 eyes of 64 patients with primary or secondary glaucoma. Participants underwent both HFA and MRF perimetry in a non-randomized sequence. Agreement was analyzed using intraclass correlation coefficients (ICC) and Bland–Altman analysis. Test–retest reliability of MRF was evaluated in 47 participants after 4 weeks. Acceptability was assessed via questionnaires.

Results

MRF demonstrated comparable reliability indices to HFA (p > 0.05), although these findings do not establish equivalent clinical reliability due to differences in platform-specific definitions. MRF demonstrated excellent test–retest reliability for MD (ICC 0.993), PD (ICC 0.992), and VC (ICC 0.992; all p < 0.001). Compared with HFA, MRF produced significantly less negative MD (−6.27 ± 5.55 vs. −8.32 ± 5.47 dB, p < 0.001) and higher PSD/PD (7.48 ± 3.26 vs. 6.33 ± 4.11 dB, p < 0.001), while VFI/VC did not differ significantly (p = 0.808). Overall agreement was good-to-excellent MD (ICC 0.949), PSD/PD (ICC 0.880), and VFI/VC (ICC 0.930). However, exploratory severity-stratified Bland–Altman analysis suggested greater variability in moderate and severe glaucoma. MRF was significantly faster than HFA (4.22 ± 0.81 vs. 5.46 ± 1.33 min, p < 0.001). All patients reported it was easy and comfortable.

Conclusions

MRF provides excellent test–retest reliability, shorter testing duration, and high patient acceptability. While overall agreement is high, systematic differences and greater advanced-stage variability prevent direct interchangeability with HFA. Instead, MRF serves as a practical, complementary platform for accessible, frequent testing.

Schlagwörter

Stichwörter der Autor:innen

Humphrey Field Analyzer (HFA)Melbourne Rapid Fields (MRF)glaucomatest–retest reliabilityvisual field indices

Autor:innen und Institutionen

  • Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, Malaysia.
  • Department of Ophthalmology, Hospital Canselor Tuanku Muhriz, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, Malaysia.

Zitieren

APA

Basri, M. H., Cheng, T. C., Nasaruddin, R. A., & Hamzah, J. C. (2026). Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma. Diagnostics, 16(21), 3528. https://doi.org/10.3390/diagnostics16213528

Vancouver

Basri MH, Cheng TC, Nasaruddin RA, Hamzah JC. Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma. Diagnostics. 2026;16(21):3528. doi:10.3390/diagnostics16213528

BibTeX
@article{Basri2026,
  author = {Basri, Murshidah Hassan and Cheng, Teck Chee and Nasaruddin, Rona Asnida and Hamzah, Jemaima Che},
  title = {Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {21},
  pages = {3528},
  doi = {10.3390/diagnostics16213528}
}
Kostenlos starten →