Comparison of Diagnostic Performance of Whole-Body 360° CZT Bone SPECT/CT and Planar Bone Scintigraphy in Detecting Bone Metastasis in Small Cell Lung Cancer

Sang Mi Lee, Su Jin Jang, Ju Ock Na, Ki Hyun Seo, Nam Hun Heo, Jeong Won Lee

Diagnostics · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Background/Objectives: We aimed to compare the diagnostic performances of planar bone scintigraphy and whole-body 360° cadmium–zinc–telluride (CZT) bone single-photon emission computed tomography/computed tomography (SPECT/CT) in detecting bone metastasis in patients with small cell lung cancer (SCLC). Methods: We retrospectively evaluated two separate, non-randomized cohorts of 175 patients with SCLC who underwent staging bone scintigraphy, comprising 93 and 82 patients who underwent planar bone scintigraphy using a conventional dual-head gamma camera and whole-body bone SPECT/CT using a full-ring 360° CZT camera, respectively. Both imaging examinations were visually assessed and compared using patient- and lesion-based analyses of their diagnostic performances. Results: Whole-body bone SPECT/CT showed fewer equivocal findings and almost perfect inter-reader agreement. On the patient-based analysis, whole-body bone SPECT/CT demonstrated higher unadjusted observed diagnostic accuracy than planar bone scintigraphy (87.8% vs. 73.1%; p = 0.016), with higher observed sensitivity (79.2% vs. 53.3%), specificity (91.4% vs. 82.5%), positive predictive value (79.2% vs. 59.3%) and negative predictive value (91.4% vs. 78.8%). However, on a lesion-based analysis, whole-body bone SPECT/CT exhibited a low sensitivity of 47.5%, with particularly low detection rates for spine and pelvic metastases (29.4%), despite showing higher observed sensitivity than planar bone scintigraphy (20.1%). Conclusions: In two separate retrospective cohorts of SCLC patients, whole-body bone SPECT/CT showed higher unadjusted observed patients-based diagnostic performance than planar bone scintigraphy. However, its lesion-level sensitivity remained low, particularly in the spine and pelvis.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Sang Mi Lee, Su Jin Jang, Ju Ock Na, Ki Hyun Seo, Nam Hun Heo, Jeong Won Lee
Quelle
Diagnostics
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
2075-4418
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Sang Mi Lee, Su Jin Jang, Ju Ock Na, Ki Hyun Seo, Nam Hun Heo, Jeong Won Lee (2026). Comparison of Diagnostic Performance of Whole-Body 360° CZT Bone SPECT/CT and Planar Bone Scintigraphy in Detecting Bone Metastasis in Small Cell Lung Cancer. Diagnostics. https://doi.org/10.3390/diagnostics16172838
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1