EUVIMEDEuropean Health Evidence
Uhr 7/7Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Radiation and Contrast Medium Dosage Optimization of Coronary CT Angiography While Combining Personalized Patient Protocol Technology and Automated Tube Voltage Selection Technology

Jingkun Sun, Yang Zhou, Ge Zhang, Lijun Zhang, Xinnan Shen, Zhiwei Zhang

Diagnostics · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Objective: This study aims to investigate whether combining automated tube voltage selection (ATVS) with P3T for contrast injection in coronary computed tomography angiography (CCTA) allows for patient-tailored scanning protocols. Specifically, we assessed whether this combination maintains equivalent image quality and adequate diagnostic image quality. Methods: This retrospective study included 378 patients who underwent CCTA using ATVS and P3T technologies. We divided the patients into three groups based on the scanning tube voltage: 70-, 80-, and 90-kV groups. Furthermore, each group was divided into sequence and spiral scanning subgroups based on the acquisition method. The CM injection volume and rate, volume CT dose index (CTDIvol), and dose–length product (DLP) were recorded. The CT value of the enhanced coronary artery, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated by artery segment. Image quality was evaluated using a four-point grading scale in a double-blind manner. Results: The SNR did not differ among the groups in any segments (p > 0.05). And the subjective image quality showed only minor differences among the groups. The body weight, which determines ATVS and P3T protocol algorithm, is positively correlated with the automatic tube voltage, CM injection volume, and effective radiation dose. Furthermore, when using the same tube voltage under the combined ATVS and P3T protocols, sequence scanning yielded a lower radiation dose than spiral scanning (p < 0.05). Conclusions: CCTA combining ATVS and P3T technology enables individualized scanning protocols while maintaining adequate diagnostic image quality.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Jingkun Sun, Yang Zhou, Ge Zhang, Lijun Zhang, Xinnan Shen, Zhiwei Zhang
Quelle
Diagnostics
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
2075-4418
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Jingkun Sun, Yang Zhou, Ge Zhang, Lijun Zhang, Xinnan Shen, Zhiwei Zhang (2026). Radiation and Contrast Medium Dosage Optimization of Coronary CT Angiography While Combining Personalized Patient Protocol Technology and Automated Tube Voltage Selection Technology. Diagnostics. https://doi.org/10.3390/diagnostics16172804
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1