Fachartikel in der Zeitschrift Diagnostics, online erschienen am 27.07.2026. Verfasst von Soha Abdulrahman Alonaizan und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pre-analytical errors account for the majority of failures across the total testing process. This study evaluated pre-analytical performance in a tertiary-care biochemistry laboratory in Riyadh, Saudi Arabia, using IFCC-aligned Quality Indicators (QIs), Six Sigma metrics, and structured Root Cause Analysis (RCA).

Methods

A retrospective analysis of all biochemistry tests processed between January and December 2024 at a tertiary-care hospital was conducted. Rejected tests were classified into seven IFCC-aligned QI categories. Sigma metrics assessed process capability, Pareto analysis identified the vital few contributors, and RCA using the Ishikawa framework identified human, equipment, environmental, and process-related factors. Rejection patterns were described by department and work shift.

Results

Of 845,647 tests performed, 10,783 (1.28%) were rejected, yielding an overall process capability of 3.89σ (Minimum Acceptable). Hemolysis was the leading cause (8186 tests; 75.92%) at 3.97σ, the only indicator classified as High against the IFCC WG-LEPS registry. The remaining six indicators demonstrated Good to Very Good performance (4.59σ–5.33σ). Pareto analysis identified hemolysis and inappropriate tube use (7.60%) as the vital few, jointly responsible for 83.52% of rejections. RCA implicated venipuncture technique, needle gauge selection, workload pressure, and prolonged tourniquet application as key contributors. The Emergency Department generated the highest inpatient rejection burden (38.7%).

Conclusions

Although the overall rejection rate compared favorably with international benchmarks, hemolysis was the principal process vulnerability, with inappropriate tube selection as a secondary target. Recommended quality improvement strategies include structured phlebotomy training, real-time hemolysis index feedback, and Emergency Department-specific initiatives; structural solutions such as dedicated inpatient phlebotomy services warrant prospective evaluation alongside training-based interventions.

Schlagwörter

Stichwörter der Autor:innen

Six Sigmahemolysislaboratory medicinepre-analytical errorsquality indicatorsroot cause analysisspecimen handlingspecimen rejection

Autor:innen und Institutionen

  • College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia.
  • Security Forces Hospital, Riyadh 11481, Saudi Arabia.

ORCID-Profile: Shoukat Ali Arain

Zitieren

APA

Alonaizan, S. A., Alenaizan, N. A., Binjomah, A. Z., Aldosari, S., & Arain, S. A. (2026). Evaluation of Pre-Analytical Performance Using IFCC Quality Indicators, Six Sigma Metrics and Root Cause Analysis in a Biochemistry Laboratory—A Retrospective Study. Diagnostics, 16(15), 2357. https://doi.org/10.3390/diagnostics16152357

Vancouver

Alonaizan SA, Alenaizan NA, Binjomah AZ, Aldosari S, Arain SA. Evaluation of Pre-Analytical Performance Using IFCC Quality Indicators, Six Sigma Metrics and Root Cause Analysis in a Biochemistry Laboratory—A Retrospective Study. Diagnostics. 2026;16(15):2357. doi:10.3390/diagnostics16152357

BibTeX
@article{Alonaizan2026,
  author = {Alonaizan, Soha Abdulrahman and Alenaizan, Nadiah A and Binjomah, Abdulwahab Z and Aldosari, Salman and Arain, Shoukat Ali},
  title = {Evaluation of Pre-Analytical Performance Using IFCC Quality Indicators, Six Sigma Metrics and Root Cause Analysis in a Biochemistry Laboratory—A Retrospective Study},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {15},
  pages = {2357},
  doi = {10.3390/diagnostics16152357}
}
Kostenlos starten →