Conjunctival Vascular Metrics Using Automated Vessel Detection from Slit Lamp Images for Hyperemia Severity Assessment
Diagnostics · 01.07.2026 · 16 (13) · 2066
DOI: 10.3390/diagnostics16132066 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 01.07.2026. Verfasst von Damon Wong und 8 weiteren Autor:innen. Beteiligte Einrichtung: Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 168751, Singapore. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Medical Research Council, National Research Foundation, Agency for Science, Technology and Research.
Abstract (Originalsprache)
Background/Objectives: Conjunctival hyperemia is a common clinical finding in clinical practice; however there are significant differences between graders. Vessel detection using deep-learning approaches could enable more objective measures. We aimed to evaluate vascular metrics derived from automated vessel detection and compare these metrics with manual severity gradings.
Methods
Slit lamp images from 139 glaucoma patients were included. Images from 103 participants were used as the primary development dataset and the remaining as a validation subset. The images were independently graded by two graders for conjunctival hyperemia using the Efron Grading Scheme. Conjunctival vessels were detected using an automated vessel detection pipeline based on semi-supervised learning. Vessel density, fractal dimension and tortuosity were calculated and compared with the manual Efron grades.
Results
Grading of conjunctival hyperemia between the two graders were consistent (Spearman’s rho: 0.79; ICC: 0.79 [95%CI: 0.72–0.84]) but showed significant differences with a higher proportion of differences in the moderate grades. Of the vascular metrics, vessel density showed significant associations with the individual Efron grading and against the mean Efron grading (0.78, p < 0.001). Fractal dimension was significantly associated with the mean Efron grading (0.55, p < 0.001). Agreements were similar in the subset (vessel density, 0.80, p < 0.001; fractal dimension 0.62, p < 0.001). Vessel tortuosity showed lower agreements (
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 168751, Singapore.
- SERI-NTU Advanced Ocular Engineering (STANCE) Program, Singapore 308232, Singapore.
- Ophthalmology and Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore 169857, Singapore.
- Department of Ophthalmology, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania.
- Department of Ophthalmology, Emergency University Hospital, 050474 Bucharest, Romania.
- Department of Clinical Pharmacology, Medical University of Vienna, 1090 Vienna, Austria.
ORCID-Profile: Damon Wong, Leila Sara Eppenberger, Radu Bucsan
Förderung
- National Medical Research Council
- National Research Foundation
- Agency for Science, Technology and Research
- National Health Innovation Centre
- SingHealth Duke-NUS Academic Medical Centre
- Duke-NUS Medical School
- Singapore Eye Research Institute and Nanyang Technological University
- Singapore Eye Research Institute
Zitieren
APA
Wong, D., Ng, Y., Eppenberger, L. S., Toma, E., Bucsan, R., Deleanu, D. G., Cherecheanu, A. P., Garhöfer, G., & Schmetterer, L. (2026). Conjunctival Vascular Metrics Using Automated Vessel Detection from Slit Lamp Images for Hyperemia Severity Assessment. Diagnostics, 16(13), 2066. https://doi.org/10.3390/diagnostics16132066
Vancouver
Wong D, Ng Y, Eppenberger LS, Toma E, Bucsan R, Deleanu DG, et al. Conjunctival Vascular Metrics Using Automated Vessel Detection from Slit Lamp Images for Hyperemia Severity Assessment. Diagnostics. 2026;16(13):2066. doi:10.3390/diagnostics16132066
BibTeX
@article{Wong2026,
author = {Wong, Damon and Ng, Yvonne and Eppenberger, Leila Sara and Toma, Eduard and Bucsan, Radu and Deleanu, Dan George and Cherecheanu, Alina Popa and Garhöfer, Gerhard and Schmetterer, Leopold},
title = {Conjunctival Vascular Metrics Using Automated Vessel Detection from Slit Lamp Images for Hyperemia Severity Assessment},
journal = {Diagnostics},