Improving Shape-Sensing Robotic-Assisted Bronchoscopy Outcomes with Mobile Cone-Beam Computed Tomography Guidance
Diagnostics · 04.09.2024 · 14 (17) · 1955
DOI: 10.3390/diagnostics14171955 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 04.09.2024. Verfasst von Sami I Bashour und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pulmonary and Critical Care Medicine, Michael E. DeBakey VA Medical Center, Houston, TX 77030, USA. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, Siemens, Cancer Center.
Abstract (Originalsprache)
Background
Computed tomography to body divergence (CTBD) is one of the main barriers to bronchoscopic techniques for the diagnosis of peripherally located lung nodules. Cone-beam CT (CBCT) guidance is being rapidly adopted to correct for this phenomenon and to potentially increase diagnostic outcomes. In this trial, we hypothesized that the addition of mobile CBCT (m-CBCT) could improve the rate of tool in lesion (TIL) and the diagnostic yield of shape-sensing robotic-assisted bronchoscopy (SS-RAB).
Methods
This was a prospective, single-arm study, which enrolled patients with peripheral lung nodules of 1–3 cm and compared the rate of TIL and the diagnostic yield of SS-RAB alone and combined with mCBCT.
Results
A total of 67 subjects were enrolled, the median nodule size was 1.7 cm (range, 0.9–3 cm). TIL was achieved in 23 patients (34.3%) with SS-RAB alone, and 66 patients (98.6%) with the addition of mCBCT (p < 0.0001). The diagnostic yield of SS-RAB alone was 29.9% (95% CI, 29.3–42.3%) and it was 86.6% (95% CI, 76–93.7%) with the addition of mCBCT (p < 0.0001). There were no pneumothoraxes or any bronchoscopy-related complications, and the median total dose–area product (DAP) was 50.5 Gy-cm2.
Conclusions
The addition of mCBCT guidance to SS-RAB allows bronchoscopists to compensate for CTBD, leading to an increase in TIL and diagnostic yield, with acceptable radiation exposure.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pulmonary and Critical Care Medicine, Michael E. DeBakey VA Medical Center, Houston, TX 77030, USA.
- Department of Pulmonary and Critical Care Medicine, Ochsner Health Rush, Meridian, MS 39301, USA.
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
- Siemens Medical Solutions USA Inc., Malvern 19355, PA, USA.
- Siemens Healthcare GmbH, 91301 Forchheim, Germany.
- Department of Pulmonary Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
ORCID-Profile: Sami I Bashour, Asad Khan, Juhee Song, David E Ost
Förderung
- NCI NIH HHS
- Siemens
- Cancer Center
Zitieren
APA
Bashour, S. I., Khan, A., Song, J., Chintalapani, G., Kleinszig, G., Sabath, B. F., Lin, J., Grosu, H. B., Jimenez, C. A., Eapen, G. A., Ost, D. E., Sarkiss, M., & Casal, R. F. (2024). Improving Shape-Sensing Robotic-Assisted Bronchoscopy Outcomes with Mobile Cone-Beam Computed Tomography Guidance. Diagnostics, 14(17), 1955. https://doi.org/10.3390/diagnostics14171955
Vancouver
Bashour SI, Khan A, Song J, Chintalapani G, Kleinszig G, Sabath BF, et al. Improving Shape-Sensing Robotic-Assisted Bronchoscopy Outcomes with Mobile Cone-Beam Computed Tomography Guidance. Diagnostics. 2024;14(17):1955. doi:10.3390/diagnostics14171955
BibTeX
@article{Bashour2024,
author = {Bashour, Sami I and Khan, Asad and Song, Juhee and Chintalapani, Gouthami and Kleinszig, Gerhard and Sabath, Bruce F and Lin, Julie and Grosu, Horiana B and Jimenez, Carlos A and Eapen, Georgie A and Ost, David E and Sarkiss, Mona and Casal, Roberto F},
title = {Improving Shape-Sensing Robotic-Assisted Bronchoscopy Outcomes with Mobile Cone-Beam Computed Tomography Guidance},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {17},
pages = {1955},
doi = {10.3390/diagnostics14171955}
}
EUVIMED