Cardio-Dense: Diagnosis of Cardiac Abnormalities Based on Phonocardiogram Using Improved Swin Transformer Through Lightweight Dense Blocks
Diagnostics · 2026-05-07 · 16 (10) · 1421
DOI: 10.3390/diagnostics16101421 ↗At a glance
Journal article in Diagnostics, published online on 2026-05-07. Written by Alaa E S Ahmed and 2 co-authors. Institution: College of Computer and Information Sciences, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11432, Saudi Arabia. 41 references. The full text is freely available (open access, CC BY 4.0). Funded by: This work was supported and funded by the Deanship of Scientific Research at Imam Mohammad Ibn Saud Islamic University (IMSIU) (grant number IMSIU-DDRSP2601)..
Abstract (original language)
Background
Cardiovascular diseases (CVDs) are among the top sources of mortality worldwide. To properly diagnose cardiovascular diseases, a low-cost remedy based on phonocardiography (PCG) signals must be proposed. Several deep learning (DL)-driven CVD systems are now being developed to identify various phases of the disease. Nevertheless, the approaches’ accuracy falls short of expectations, and they necessitate substantial processing resources and training data.
Methods
This paper proposes Cardio-Dense, a hybrid framework for multi-class CVD detection from phonocardiogram signals. The PCG waveform is first denoised in the wavelet domain and then converted into a 2D time–frequency spectrogram using continuous wavelet transform (CWT). We design a joint architecture that combines a Swin transformer for capturing global contextual dependencies with lightweight DenseBlocks for efficient local feature refinement, enabling robust learning from PCG spectrograms across five disease classes.
Results
Experiments on PCG datasets achieve up to 0.977 accuracy, 0.975 sensitivity, 0.992 specificity, 0.978 F1-score, 0.978 AUC, and 0.976 precision, while maintaining low computational overhead suitable for real-time inference.
Conclusions
The findings indicate that the proposed model provides an economical, non-invasive method for preliminary signal-level identification of multi-class heart valve diseases. It benefits clinicians by decreasing the need for arduous and error-prone manual PCG analysis. Furthermore, it offers quick, near-real-time categorization suitable for clinical and portable applications.
Subjects
Author keywords
Authors and institutions
- College of Computer and Information Sciences, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11432, Saudi Arabia.
ORCID profiles: Alaa E S Ahmed, Mostafa E A Ibrahim, Yassine Daadaa
Funding
- This work was supported and funded by the Deanship of Scientific Research at Imam Mohammad Ibn Saud Islamic University (IMSIU) (grant number IMSIU-DDRSP2601).
Cite
APA
Ahmed, A. E. S., Ibrahim, M. E. A., & Daadaa, Y. (2026). Cardio-Dense: Diagnosis of Cardiac Abnormalities Based on Phonocardiogram Using Improved Swin Transformer Through Lightweight Dense Blocks. Diagnostics, 16(10), 1421. https://doi.org/10.3390/diagnostics16101421
Vancouver
Ahmed AES, Ibrahim MEA, Daadaa Y. Cardio-Dense: Diagnosis of Cardiac Abnormalities Based on Phonocardiogram Using Improved Swin Transformer Through Lightweight Dense Blocks. Diagnostics. 2026;16(10):1421. doi:10.3390/diagnostics16101421
BibTeX
@article{Ahmed2026,
author = {Ahmed, Alaa E S and Ibrahim, Mostafa E A and Daadaa, Yassine},
title = {Cardio-Dense: Diagnosis of Cardiac Abnormalities Based on Phonocardiogram Using Improved Swin Transformer Through Lightweight Dense Blocks},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {10},
pages = {1421},
doi = {10.3390/diagnostics16101421}
}
EUVIMED