EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Establishing Local Diagnostic Reference Levels (DRLs) for Adult Computed Tomography in Emirates Health Services Hospitals: A Multicenter Dose Survey

Amina Aljasmi, Sheikha Almsafri, Suhaib Alameen, Hatem Ghonim, Maryam Alhajri, Amna Alshamsi, Sherif Hani Elkelsh, Mohammed Abuzaid iD

Diagnostics · 30.04.2026 · 16 (9) · 1353

DOI: 10.3390/diagnostics16091353 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 30.04.2026. Verfasst von Amina Aljasmi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, Emirates Health Services, Dubai P.O. Box 70225, United Arab Emirates. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to establish local Diagnostic Reference Levels (DRLs) for adult computed tomography (CT) across Emirates Health Services (EHS) hospitals in the United Arab Emirates.

Methods

A retrospective multicenter survey included 1257 adult patients from seven EHS hospitals who underwent six routine CT protocols: head without contrast (n = 375), chest without contrast (n = 403), chest with contrast (n = 50), abdomen–pelvis without contrast (n = 204), abdomen–pelvis with contrast (n = 164), and chest–abdomen–pelvis (n = 61). Only single-phase, standard-range examinations were included. Examinations with major protocol deviations, extended scan ranges, or manual exposure overrides were excluded. CTDIvol and DLP were extracted from DICOM dose reports and reviewed against protocol definitions and scanner dose documentation. Local DRLs were defined as the 75th percentile of the dose distribution for each protocol, and median values were reported as achievable dose indicators.

Results

Inter-hospital variability was observed across all protocols, particularly for abdomen–pelvis and chest–abdomen–pelvis examinations. The proposed DLP-based local DRLs (mGy·cm) were: head without contrast, 1179.6; chest without contrast, 425.0; chest with contrast, 1238.0; abdomen–pelvis without contrast, 637.2; abdomen–pelvis with contrast, 1269.9; and chest–abdomen–pelvis, 1411.5. Median values indicated achievable doses below the 75th percentile for all protocols. Compared with selected international studies, abdomen–pelvis doses were broadly comparable, whereas head and chest doses were somewhat higher.

Conclusions

This study provides a coordinated multicenter baseline for adult CT local DRLs across EHS hospitals. The findings support protocol harmonization, scan-length optimization, targeted staff training, and integration with dose-monitoring systems to strengthen CT dose optimization and patient safety and to inform future updates of UAE national DRLs.

Schlagwörter

Stichwörter der Autor:innen

CTDIvolComputed Tomography (CT)Diagnostic Reference Levels (DRLs)Dose-Length Product (DLP)patient safetyradiation dose optimization

Autor:innen und Institutionen

  • Radiology Department, Emirates Health Services, Dubai P.O. Box 70225, United Arab Emirates.
  • Radiation Protection Center, Radiology Department, Emirates Health Services, Dubai P.O. Box 70225, United Arab Emirates.
  • Unison Capital Investment LLC, Dubai Hills Estate, Dubai P.O. Box 66212, United Arab Emirates.
  • Department of Medical Diagnostic Imaging, College of Health Sciences, University of Sharjah, Sharjah P.O. Box 27272, United Arab Emirates.

ORCID-Profile: Mohammed Abuzaid

Zitieren

APA

Aljasmi, A., Almsafri, S., Alameen, S., Ghonim, H., Alhajri, M., Alshamsi, A., Elkelsh, S. H., & Abuzaid, M. (2026). Establishing Local Diagnostic Reference Levels (DRLs) for Adult Computed Tomography in Emirates Health Services Hospitals: A Multicenter Dose Survey. Diagnostics, 16(9), 1353. https://doi.org/10.3390/diagnostics16091353

Vancouver

Aljasmi A, Almsafri S, Alameen S, Ghonim H, Alhajri M, Alshamsi A, et al. Establishing Local Diagnostic Reference Levels (DRLs) for Adult Computed Tomography in Emirates Health Services Hospitals: A Multicenter Dose Survey. Diagnostics. 2026;16(9):1353. doi:10.3390/diagnostics16091353

BibTeX
@article{Aljasmi2026,
  author = {Aljasmi, Amina and Almsafri, Sheikha and Alameen, Suhaib and Ghonim, Hatem and Alhajri, Maryam and Alshamsi, Amna and Elkelsh, Sherif Hani and Abuzaid, Mohammed},
  title = {Establishing Local Diagnostic Reference Levels (DRLs) for Adult Computed Tomography in Emirates Health Services Hospitals: A Multicenter Dose Survey},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {9},
  pages = {1353},
  doi = {10.3390/diagnostics16091353}
}
Kostenlos starten →