Optimizing Reconstruction Parameters for Detecting Peripheral In-Stent Restenosis with Photon-Counting Detector CT: A Phantom Study

Yiheng Tan iD, Joost F Hop iD, Magdalena Dobrolinska, Xinlin Zheng iD, Evie J I Hoeijmakers iD, Jean-Paul P M de Vries iD, Marcel J W Greuter iD, Reinoud P H Bokkers iD

Diagnostics · 22.04.2026 · 16 (9) · 1253

DOI: 10.3390/diagnostics16091253 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 22.04.2026. Verfasst von Yiheng Tan und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: To determine the optimal reconstruction parameters for accurate visualization of peripheral in-stent restenosis using photon-counting detector CT (PCD-CT), and to evaluate its potential advantages over energy-integrated detector CT (EID-CT).

Methods

Endovascular peripheral stents with varying degrees of in-stent restenosis were scanned in a custom-made phantom using EID-CT (Somatom Force) and PCD-CT (Naeotom Alpha) under clinical acquisition protocols. EID-CT images were reconstructed with Bv40 and Bv59 kernels at 512 matrices. PCD-CT data were acquired in standard-resolution (SR) and ultra-high-resolution (UHR) modes. In both modes, images were reconstructed with multiple kernels (Bv40, Bv56 and Bv72) and matrix sizes (512 and 1024 matrix). In SR mode, additional virtual monoenergetic images (40–100 keV) were generated, while UHR mode included only polychromatic reconstructions. Quantitative image quality (noise, contrast, contrast-to-noise ratio [CNR]) was measured, and two blinded readers performed qualitative assessments of restenosis visualization.

Results

PCD-CT with SR mode at VMI 40 keV achieved the highest image contrast and CNR, significantly outperforming EID-CT and PCD-CTUHR under matched conditions (all p < 0.05). The sharper reconstruction kernel further enhanced the image contrast and improved subjective visualization despite increased image noise. Both readers ranked PCD-CTSR-Bv72-40keV at 1024 matrix highest for detecting all degrees of restenosis, with excellent inter-reader agreement (ρ > 0.80).

Conclusions

PCD-CT in SR mode at VMI 40 keV, specifically using the Bv72 kernel with a 1024 matrix, optimizes the visualization of peripheral in-stent restenosis. Compared to EID-CT, PCD-CT provides superior image quality and detectability of restenosis.

Schlagwörter

Stichwörter der Autor:innen

computed tomographyin-stent restenosisperipheral arterial diseasephoton-counting detector CTvirtual monoenergetic image

Autor:innen und Institutionen

  • Department of Radiology, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
  • Department of Nuclear Medicine and Molecular Imaging, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
  • Division of Cardiology and Structural Heart Diseases, Medical University of Silesia, 40-514 Katowice, Poland.
  • Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, 6202 AZ Maastricht, The Netherlands.
  • CARIM School for Cardiovascular Diseases, Maastricht University, 6229 ER Maastricht, The Netherlands.
  • Department of Surgery, Division of Vascular Surgery, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.

ORCID-Profile: Yiheng Tan, Joost F Hop, Xinlin Zheng, Evie J I Hoeijmakers, Jean-Paul P M de Vries, Marcel J W Greuter, Reinoud P H Bokkers

Zitieren

APA

Tan, Y., Hop, J. F., Dobrolinska, M., Zheng, X., Hoeijmakers, E. J. I., de Vries, J. P. M., Greuter, M. J. W., & Bokkers, R. P. H. (2026). Optimizing Reconstruction Parameters for Detecting Peripheral In-Stent Restenosis with Photon-Counting Detector CT: A Phantom Study. Diagnostics, 16(9), 1253. https://doi.org/10.3390/diagnostics16091253

Vancouver

Tan Y, Hop JF, Dobrolinska M, Zheng X, Hoeijmakers EJI, de Vries JPM, et al. Optimizing Reconstruction Parameters for Detecting Peripheral In-Stent Restenosis with Photon-Counting Detector CT: A Phantom Study. Diagnostics. 2026;16(9):1253. doi:10.3390/diagnostics16091253

BibTeX
@article{Tan2026,
  author = {Tan, Yiheng and Hop, Joost F and Dobrolinska, Magdalena and Zheng, Xinlin and Hoeijmakers, Evie J I and de Vries, Jean-Paul P M and Greuter, Marcel J W and Bokkers, Reinoud P H},
  title = {Optimizing Reconstruction Parameters for Detecting Peripheral In-Stent Restenosis with Photon-Counting Detector CT: A Phantom Study},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {9},
  pages = {1253},
  doi = {10.3390/diagnostics16091253}
}
Kostenlos starten →