Diagnostic accuracy of photon-counting detector CT for detection of coronary in-stent restenosis
Cardiovascular Revascularization Medicine · 2026-09
DOI: 10.1016/j.carrev.2026.09.009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cardiovascular Revascularization Medicine, 2026-09. Verfasst von Karl Aramouni und 4 weiteren Autor:innen. Beteiligte Einrichtung: Houston Methodist DeBakey Heart & Vascular Center, 6565 Fannin St Suite 1901, Houston, TX, 77030, USA. Die Arbeit nennt 19 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Photon-counting detector computed tomography (PCD-CT) offers improved spatial resolution and reduced blooming artifacts compared with conventional CT, potentially improving visualization of coronary stents. We evaluated the diagnostic performance of PCD-CT for detecting significant coronary in-stent restenosis (ISR) using invasive coronary angiography (ICA) as the reference standard. METHODS: This retrospective, single-center diagnostic-accuracy study included consecutive adults with prior coronary stenting who underwent clinically indicated PCD-CT followed by ICA between February 2025 and January 2026. The primary outcome was the diagnostic performance of PCD-CT for detecting significant ISR, defined as >50% luminal diameter stenosis, on a per-stent basis. Secondary analyses evaluated patient-level performance and exploratory differences according to stent diameter, length, and location. RESULTS: The study included 52 patients (mean age, 70.5 ± 9.7 years; 83% male) with 69 evaluated stents. Significant ISR was present on ICA in 16 stents. PCD-CT correctly identified 12 of 16 stents with ISR and excluded ISR in 44 of 53 stents without ISR, corresponding to a sensitivity of 75.0%, specificity of 83.0%, positive predictive value of 57.1%, negative predictive value of 91.7%, and area under the curve (AUC) of 0.79 (95% CI, 0.67-0.91). Patient-level sensitivity was 86.7%, specificity was 85.7%, and AUC was 0.86 (95% CI, 0.76-0.97). Diagnostic performance was numerically higher in stents ≥3 mm than in stents
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Houston Methodist DeBakey Heart & Vascular Center, 6565 Fannin St Suite 1901, Houston, TX, 77030, USA.
- Houston Methodist DeBakey Heart & Vascular Center, 6565 Fannin St Suite 1901, Houston, TX, 77030, USA. Electronic address: wahmed@houstonmethodist.org.
Zitieren
APA
Aramouni, K., Kharsa, C., Sarkis, P., Shah, A. R., & Ahmed, W. (2026). Diagnostic accuracy of photon-counting detector CT for detection of coronary in-stent restenosis. Cardiovascular Revascularization Medicine. https://doi.org/10.1016/j.carrev.2026.09.009
Vancouver
Aramouni K, Kharsa C, Sarkis P, Shah AR, Ahmed W. Diagnostic accuracy of photon-counting detector CT for detection of coronary in-stent restenosis. Cardiovascular Revascularization Medicine. 2026. doi:10.1016/j.carrev.2026.09.009
BibTeX
@article{Aramouni2026,
author = {Aramouni, Karl and Kharsa, Chloe and Sarkis, Patrick and Shah, Alpesh R and Ahmed, Waleed},
title = {Diagnostic accuracy of photon-counting detector CT for detection of coronary in-stent restenosis},
journal = {Cardiovascular Revascularization Medicine},
year = {2026},
doi = {10.1016/j.carrev.2026.09.009}
}
EUVIMED