EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

From Ultrasound to Histopathology: Agreement Analysis and Depth Correction Model for Basal Cell Carcinoma Using a Portable 20 MHz High-Frequency Ultrasound Device

Cristina Popescu iD, Carmen Andrada Iliescu iD, Andreea Mihaela Truica, Liliana Gabriela Popa iD, Andrei Ludovic Porosnicu, Irina Tudose, Carmen Boeru, Marius Nicolae Popescu iD

Diagnostics · 25.03.2026 · 16 (7) · 978

DOI: 10.3390/diagnostics16070978 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 25.03.2026. Verfasst von Cristina Popescu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oncologic Dermatology, Elias Emergency University Hospital, Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

High-frequency ultrasound (HFUS) represents a valuable non-invasive imaging modality for assessing cutaneous tumors. In basal cell carcinoma (BCC), preoperative estimation of tumor depth may support therapeutic decision-making and surgical planning. However, agreement between HFUS-derived and histopathologic depth measurements remains incompletely characterized, particularly with 20 MHz probes in routine clinical practice.

Objectives

To evaluate agreement between 20 MHz HFUS and histopathology for BCC tumor depth using Bland–Altman analysis and to derive a preliminary correction equation to estimate histologic depth from HFUS measurements.

Methods

This prospective observational pilot study included 15 patients with 16 histologically confirmed BCC lesions. All lesions underwent preoperative 20 MHz HFUS followed by surgical excision, with HFUS-derived tumor depth compared with histopathologic depth. Agreement was assessed using Bland–Altman analysis, and linear regression was performed to derive a preliminary correction equation.

Results

Sixteen BCC lesions were analyzed. The mean difference between HFUS and histopathologic tumor depth was −0.07 mm, with 95% limits of agreement from −1.58 to +1.45 mm. HFUS and histopathologic depth measurements were highly correlated (R2 = 0.99). A correction equation was derived: estimated histopathologic depth (mm) = −0.52 + 1.10 × HFUS depth (mm).

Conclusions

Twenty MHz HFUS demonstrated good agreement with histopathology for tumor depth assessment in BCC, with clinically acceptable variability. The proposed correction equation may improve interpretation of HFUS measurements; however, further validation in larger cohorts is required.

Schlagwörter

Stichwörter der Autor:innen

Bland–Altman analysisbasal cell carcinomahigh-frequency ultrasoundnon-invasive imagingtumor depth

Autor:innen und Institutionen

  • Department of Oncologic Dermatology, Elias Emergency University Hospital, Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania.
  • Clinic of Dermatology, Elias Emergency University Hospital, 011461 Bucharest, Romania.
  • Department of Plastic and Reconstructive Surgery, Elias Emergency University Hospital, Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania.
  • Histopathology Department, Elias University Emergency Hospital, 011461 Bucharest, Romania.
  • Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania.
  • Department of Physical and Rehabilitation Medicine, Elias Emergency University Hospital, Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania.

ORCID-Profile: Cristina Popescu, Carmen Andrada Iliescu, Liliana Gabriela Popa, Marius Nicolae Popescu

Zitieren

APA

Popescu, C., Iliescu, C. A., Truica, A. M., Popa, L. G., Porosnicu, A. L., Tudose, I., Boeru, C., & Popescu, M. N. (2026). From Ultrasound to Histopathology: Agreement Analysis and Depth Correction Model for Basal Cell Carcinoma Using a Portable 20 MHz High-Frequency Ultrasound Device. Diagnostics, 16(7), 978. https://doi.org/10.3390/diagnostics16070978

Vancouver

Popescu C, Iliescu CA, Truica AM, Popa LG, Porosnicu AL, Tudose I, et al. From Ultrasound to Histopathology: Agreement Analysis and Depth Correction Model for Basal Cell Carcinoma Using a Portable 20 MHz High-Frequency Ultrasound Device. Diagnostics. 2026;16(7):978. doi:10.3390/diagnostics16070978

BibTeX
@article{Popescu2026,
  author = {Popescu, Cristina and Iliescu, Carmen Andrada and Truica, Andreea Mihaela and Popa, Liliana Gabriela and Porosnicu, Andrei Ludovic and Tudose, Irina and Boeru, Carmen and Popescu, Marius Nicolae},
  title = {From Ultrasound to Histopathology: Agreement Analysis and Depth Correction Model for Basal Cell Carcinoma Using a Portable 20 MHz High-Frequency Ultrasound Device},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {7},
  pages = {978},
  doi = {10.3390/diagnostics16070978}
}
Kostenlos starten →