Prospective, Multicentre Feasibility Study of Remote Colon Capsule Endoscopy Using the OMOM CC100 System
Diagnostics · 20.12.2025 · 16 (1) · 20
DOI: 10.3390/diagnostics16010020 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 20.12.2025. Verfasst von Alexandra Agache und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Research, University of Southern Denmark (SDU), 5000 Odense C, Denmark. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jinshan.
Abstract (Originalsprache)
Background and Aims: Colon capsule endoscopy (CCE) provides a non-invasive alternative to traditional colonoscopy. This study evaluated the feasibility, safety, diagnostic yield (DY), and patient satisfaction of the OMOM CC100 CCE system, with special focus on fully remote (n = 30) and partially remote (n = 89) administration across four centres to advance decentralised models.
Methods
This prospective, investigator-initiated, international multicentre feasibility study enrolled 119 patients aged 18–75 years at centres in Denmark, Sweden, Portugal, and Poland from July 2024 to May 2025. Indications included rectal bleeding, iron-deficiency anaemia, a positive faecal immunochemical test, changes in bowel habit, suspected inflammatory bowel disease (IBD), post-polypectomy or colorectal cancer (CRC) surgery surveillance, and a family history of CRC. The OMOM CC100 capsule was employed with a standardised bowel preparation regimen. Administration was fully remote in Denmark using the IntelliGI™ platform and partially remote (clinic ingestion, home completion) at the other sites. Primary outcomes encompassed procedure feasibility, completion rate (capsule excretion or anal verge visualisation), bowel cleanliness (Leighton-Rex scale ≥ 3), diagnostic yield, and patient satisfaction. Secondary measures included transit times, adverse events, and technical failures.
Results
Median age was 55.7 years (65 males, 54 females). Overall completion rate was 79%, varying by centre: Sweden (90%), Portugal (81%), Denmark (80%), and Poland (63%). Adequate bowel cleanliness was achieved in 71% of cases. Diagnostic findings included polyps (25 patients), angioectasia (20), diverticulosis (17), and mucosal inflammation (17); 42% were normal. Fully remote administration yielded 80% completion and 89.7% satisfaction. No serious adverse events occurred; overall satisfaction was 81%, with 87% preferring home-based procedures.
Conclusions
The OMOM CC100 CCE system is feasible, safe, with DY comparable to established systems. IntelliGI™-enabled remote administration promotes decentralised care, enhancing accessibility.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical Research, University of Southern Denmark (SDU), 5000 Odense C, Denmark.
- Department of Surgery, Odense University Hospital (OUH), 5000 Odense C, Denmark.
- Department of General Surgery, University of Medicine and Pharmacy 'Carol Davila', 050474 Bucharest, Romania.
- Department of Gastroenterology, Skåne University Hospital, 205 02 Malmö, Sweden.
- Department of Clinical Sciences Malmö, Lund University, 22100 Malmö, Sweden.
- Gastroenterology, Centro Hospitalar São João, 4200-319 Porto, Portugal.
ORCID-Profile: Alexandra Agache, Ervin Toth, Niels Qvist, Miguel Mascarenhas, Benedicte Schelde-Olesen, Maria Marlicz, Gabriele Wurm Johansson, Anastasios Koulaouzidis
Förderung
- Jinshan
Zitieren
APA
Agache, A., Toth, E., Qvist, N., Mascarenhas, M., Marlicz, W., Schelde-Olesen, B., Mascarenhas-Saraiva, M., Marlicz, M., Johansson, G. W., Nemeth, A., & Koulaouzidis, A. (2025). Prospective, Multicentre Feasibility Study of Remote Colon Capsule Endoscopy Using the OMOM CC100 System. Diagnostics, 16(1), 20. https://doi.org/10.3390/diagnostics16010020
Vancouver
Agache A, Toth E, Qvist N, Mascarenhas M, Marlicz W, Schelde-Olesen B, et al. Prospective, Multicentre Feasibility Study of Remote Colon Capsule Endoscopy Using the OMOM CC100 System. Diagnostics. 2025;16(1):20. doi:10.3390/diagnostics16010020
BibTeX
@article{Agache2025,
author = {Agache, Alexandra and Toth, Ervin and Qvist, Niels and Mascarenhas, Miguel and Marlicz, Wojciech and Schelde-Olesen, Benedicte and Mascarenhas-Saraiva, Miguel and Marlicz, Maria and Johansson, Gabriele Wurm and Nemeth, Artur and Koulaouzidis, Anastasios},
title = {Prospective, Multicentre Feasibility Study of Remote Colon Capsule Endoscopy Using the OMOM CC100 System},
journal = {Diagnostics},
year = {2025},
volume = {16},
number = {1},
pages = {20},
doi = {10.3390/diagnostics16010020}
}
EUVIMED