Fully Automated Photoplethysmography-Based Wearable Atrial Fibrillation Screening in a Hospital Setting

Khaled Abdelhamid iD, Pamela Reissenberger, Diana Piper iD, Nicole Koenig, Bianca Hoelz, Julia Schlaepfer, Simone Gysler, Helena McCullough, Sebastian Ramin-Wright, Anna-Lena Gabathuler, Jahnvi Khandpur, Milene Meier und 1 weitere

Diagnostics · 14.05.2025 · 15 (10) · 1233

DOI: 10.3390/diagnostics15101233 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 14.05.2025. Verfasst von Khaled Abdelhamid und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, University Hospital Basel, 4031 Basel, Switzerland. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission of Reasearch, German Federeal Ministry of Research and Education, European Commission for Research and Innovation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Atrial fibrillation (AF) remains a major risk factor for stroke. It is often asymptomatic and paroxysmal, making it difficult to detect with conventional electrocardiography (ECG). While photoplethysmography (PPG)-based devices like smartwatches have demonstrated efficacy in detecting AF, they are rarely integrated into hospital infrastructure. The study aimed to establish a seamless system for real-time AF screening in hospitalized high-risk patients using a wrist-worn PPG device integrated into a hospital’s data infrastructure.

Methods

In this investigator-initiated prospective clinical trial conducted at the University Hospital Basel, patients with a CHA2DS2-VASc score ≥ 2 and no history of AF received a wristband equipped with a PPG sensor for continuous monitoring during their hospital stay. The PPG data were automatically transmitted, analyzed, stored, and visualized. Upon detection of an absolute arrhythmia (AA) in the PPG signal, a Holter ECG was administered.

Results

The analysis encompassed 346 patients (mean age 72 ± 10 years, 175 females (50.6%), mean CHA2DS2-VASc score 3.5 ± 1.3)). The mean monitoring duration was 4.3 ± 4.4 days. AA in the PPG signal was detected in twelve patients (3.5%, CI: 1.5–5.4%), with most cases identified within 24 h (p = 0.004). There was a 1.3 times higher AA burden during the nighttime compared to daytime (p = 0.03). Compliance was high (304/346, 87.9%). No instances of AF were confirmed in the nine patients undergoing Holter ECG.

Conclusions

This study successfully pioneered an automated infrastructure for AF screening in hospitalized patients through the use of wrist-worn PPG devices. This implementation allowed for real-time data visualization and intervention in the form of a Holter ECG. The high compliance and early AA detection achieved in this study underscore the potential and relevance of this novel infrastructure in clinical practice.

Schlagwörter

Stichwörter der Autor:innen

atrial fibrillationphotoplethysmographyscreeningwearable

Autor:innen und Institutionen

  • Department of Internal Medicine, University Hospital Basel, 4031 Basel, Switzerland.
  • Preventicus GmbH, 07743 Jena, Germany.
  • Innovation Management, Department of D&ICT, University Hospital Basel, 4031 Basel, Switzerland.

ORCID-Profile: Khaled Abdelhamid, Diana Piper, Jens Eckstein

Förderung

  • European Commission of Reasearch
  • German Federeal Ministry of Research and Education
  • European Commission for Research and Innovation
  • German Federal Ministry of Education and Research

Zitieren

APA

Abdelhamid, K., Reissenberger, P., Piper, D., Koenig, N., Hoelz, B., Schlaepfer, J., Gysler, S., McCullough, H., Ramin-Wright, S., Gabathuler, A. L., Khandpur, J., Meier, M., & Eckstein, J. (2025). Fully Automated Photoplethysmography-Based Wearable Atrial Fibrillation Screening in a Hospital Setting. Diagnostics, 15(10), 1233. https://doi.org/10.3390/diagnostics15101233

Vancouver

Abdelhamid K, Reissenberger P, Piper D, Koenig N, Hoelz B, Schlaepfer J, et al. Fully Automated Photoplethysmography-Based Wearable Atrial Fibrillation Screening in a Hospital Setting. Diagnostics. 2025;15(10):1233. doi:10.3390/diagnostics15101233

BibTeX
@article{Abdelhamid2025,
  author = {Abdelhamid, Khaled and Reissenberger, Pamela and Piper, Diana and Koenig, Nicole and Hoelz, Bianca and Schlaepfer, Julia and Gysler, Simone and McCullough, Helena and Ramin-Wright, Sebastian and Gabathuler, Anna-Lena and Khandpur, Jahnvi and Meier, Milene and Eckstein, Jens},
  title = {Fully Automated Photoplethysmography-Based Wearable Atrial Fibrillation Screening in a Hospital Setting},
  journal = {Diagnostics},
  year = {2025},
  volume = {15},
  number = {10},
  pages = {1233},
  doi = {10.3390/diagnostics15101233}
}
Kostenlos starten →