EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Continuous Atrial Fibrillation Monitoring From Photoplethysmography

Pavel Antiperovitch, David Mortara, Joshua Barrios, Robert Avram, Kimberly Yee, Armeen Namjou Khaless, Ashley Cristal, Geoffrey Tison, Jeffrey Olgin

JACC: Clinical Electrophysiology · 2024-02 · 10 (2) · 334-345

DOI: 10.1016/j.jacep.2024.01.008 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2024-02. Verfasst von Pavel Antiperovitch und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Medicine and Cardiovascular Research Institute, University of California-San Francisco, San Francisco, Californ…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Deep Learning. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, NIH.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Continuous monitoring for atrial fibrillation (AF) using photoplethysmography (PPG) from smartwatches or other wearables is challenging due to periods of poor signal quality during motion or suboptimal wearing. As a result, many consumer wearables sample infrequently and only analyze when the user is at rest, which limits the ability to perform continuous monitoring or to quantify AF. OBJECTIVES: This study aimed to compare 2 methods of continuous monitoring for AF in free-living patients: a well-validated signal processing (SP) heuristic and a convolutional deep neural network (DNN) trained on raw signal. METHODS: We collected 4 weeks of continuous PPG and electrocardiography signals in 204 free-living patients. Both SP and DNN models were developed and validated both on holdout patients and an external validation set. RESULTS: The results show that the SP model demonstrated receiver-operating characteristic area under the curve (AUC) of 0.972 (sensitivity 99.6%, specificity: 94.4%), which was similar to the DNN receiver-operating characteristic AUC of 0.973 (sensitivity 92.2, specificity: 95.5%); however, the DNN classified significantly more data (95% vs 62%), revealing its superior tolerance of tracings prone to motion artifact. Explainability analysis revealed that the DNN automatically suppresses motion artifacts, evaluates irregularity, and learns natural AF interbeat variability. The DNN performed better and analyzed more signal in the external validation cohort using a different population and PPG sensor (AUC, 0.994; 97% analyzed vs AUC, 0.989; 88% analyzed). CONCLUSIONS: DNNs perform at least as well as SP models, classify more data, and thus may be better for continuous PPG monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationDeep LearningHumansPhotoplethysmographyHeuristicsMonitoring, Physiologic

Stichwörter der Autor:innen

atrial fibrillationdeep learningrhythm monitoringsignal processingsmartwatch

Autor:innen und Institutionen

  • Division of Cardiology, Department of Medicine and Cardiovascular Research Institute, University of California-San Francisco, San Francisco, California, USA.
  • Division of Cardiology, Department of Medicine and Cardiovascular Research Institute, University of California-San Francisco, San Francisco, California, USA; Bakar Computational Health Sciences Institute, University of…
  • Division of Cardiology, Department of Medicine and Cardiovascular Research Institute, University of California-San Francisco, San Francisco, California, USA; Montreal Heart Institute, Department of Medicine, University…
  • Division of Cardiology, Department of Medicine and Cardiovascular Research Institute, University of California-San Francisco, San Francisco, California, USA. Electronic address: jeffrey.olgin@ucsf.edu.

Förderung

  • NHLBI NIH HHS
  • NIH

Zitieren

APA

Antiperovitch, P., Mortara, D., Barrios, J., Avram, R., Yee, K., Khaless, A. N., Cristal, A., Tison, G., & Olgin, J. (2024). Continuous Atrial Fibrillation Monitoring From Photoplethysmography. JACC: Clinical Electrophysiology, 10(2), 334-345. https://doi.org/10.1016/j.jacep.2024.01.008

Vancouver

Antiperovitch P, Mortara D, Barrios J, Avram R, Yee K, Khaless AN, et al. Continuous Atrial Fibrillation Monitoring From Photoplethysmography. JACC: Clinical Electrophysiology. 2024;10(2):334-345. doi:10.1016/j.jacep.2024.01.008

BibTeX
@article{Antiperovitch2024,
  author = {Antiperovitch, Pavel and Mortara, David and Barrios, Joshua and Avram, Robert and Yee, Kimberly and Khaless, Armeen Namjou and Cristal, Ashley and Tison, Geoffrey and Olgin, Jeffrey},
  title = {Continuous Atrial Fibrillation Monitoring From Photoplethysmography},
  journal = {JACC: Clinical Electrophysiology},
  year = {2024},
  volume = {10},
  number = {2},
  pages = {334--345},
  doi = {10.1016/j.jacep.2024.01.008}
}
Kostenlos starten →