Photon-Counting CT Scan Phantom Study: Stability of Radiomics Features
Diagnostics · 07.03.2025 · 15 (6) · 649
DOI: 10.3390/diagnostics15060649 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 07.03.2025. Verfasst von Lama Dawi und 15 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, Gustave Roussy, 94805 Villejuif, France. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: To evaluate and optimize the reconstruction parameters of images acquired with a photon-counting CT scanner to achieve a stable radiomics signal.
Methods
Radiomics is a quantitative imaging biomarker correlated to survival in oncology patients. Implementing radiomics in clinical routine remains challenging due to the feature’s instability. Photon-counting CT scans use innovative technology directly converting photons into electrical signals resulting in higher-resolution images with reduced artifacts. This study used two organic phantoms: a natural wet sponge and a dry sausage. UHR images were acquired using a NAEOTOM Alpha photon-counting CT scan (Siemens) with a 0.4 mm slice thickness and 0.3 × 0.3 mm pixel size. Tube current and voltage were fixed at 112 mA and 120 KvP. A total of 24 reconstruction parameter sets were obtained by combining different values of kernel (Br), quantitative iterative reconstruction (QIR), spectral reconstruction (keV), and matrix size. Ten successive acquisitions were obtained on both phantoms. In total, 93 radiomic features were extracted on an ROI using the default parameters of Pyradiomic 3.0.1. Each feature’s stability was evaluated using the coefficient of variation (CV) within each parameter set.
Results
Of the 24 reconstruction parameter sets, 5 were selected based on best image quality by seven radiologists and three radiology technologists. Radiomics features were considered stable on a set when CV was less than 15%. Feature stability was impacted by reconstruction parameters and the phantom used. The most stable combination included 90 and 65 stable features of the 93 tested on the sausage and sponge respectively. It was configured with Br36, QIR 4, 60 keV, and a 1024 × 1024 matrix size.
Conclusions
Images obtained on photon-counting CT scans offer promising radiomic feature stability with optimal parameter configurations that could be applied in a clinical setting.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiology Department, Gustave Roussy, 94805 Villejuif, France.
- Laboratoire d'Imagerie Biomedicale Multimodale Paris-Saclay (BioMAPS), Université Paris-Saclay, Inserm, Centre National de la Recherche Scientifique, Commissariat à l'Energie Atomique, 94800 Villejuif, France.
- Department of Computed Tomography, Siemens Healthineers AG, 91301 Forchheim, Germany.
- Faculty of Medicine, Université Paris-Saclay, Le Kremlin Bicètre, 94270 Paris, France.
ORCID-Profile: Remy Barbe, Salma Moalla, Thibaut Pierre, Jules Dupont, Nathalie Lassau
Zitieren
APA
Dawi, L., Amouzouga, K., Muller, S., Nallet, C., Dupont, A., Vielliard, B., Croisille, C., Moussier, A., Garcia, G., Bidault, F., Barbe, R., Moalla, S., Pierre, T., Balleyguier, C., Dupont, J., & Lassau, N. (2025). Photon-Counting CT Scan Phantom Study: Stability of Radiomics Features. Diagnostics, 15(6), 649. https://doi.org/10.3390/diagnostics15060649
Vancouver
Dawi L, Amouzouga K, Muller S, Nallet C, Dupont A, Vielliard B, et al. Photon-Counting CT Scan Phantom Study: Stability of Radiomics Features. Diagnostics. 2025;15(6):649. doi:10.3390/diagnostics15060649
BibTeX
@article{Dawi2025,
author = {Dawi, Lama and Amouzouga, Kodjodenis and Muller, Serge and Nallet, Cyril and Dupont, Arnaud and Vielliard, Benoit and Croisille, Cedric and Moussier, Aurelie and Garcia, Gabriel and Bidault, François and Barbe, Remy and Moalla, Salma and Pierre, Thibaut and Balleyguier, Corinne and Dupont, Jules and Lassau, Nathalie},
title = {Photon-Counting CT Scan Phantom Study: Stability of Radiomics Features},
journal = {Diagnostics},
year = {2025},
volume = {15},
number = {6},
pages = {649},
doi = {10.3390/diagnostics15060649}
}
EUVIMED