EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fluoroscopy-Guided Percutaneous Transthoracic Needle Lung Biopsy with the Aid of Planning Cone-Beam CT: Diagnostic Accuracy and Complications

Sang Hyun Cho iD, Hyun Jung Yoon iD, Young Lee iD, Injoong Kim, Je Ryung Gil, Yeo Jin Kim iD

Diagnostics · 31.10.2024 · 14 (21) · 2441

DOI: 10.3390/diagnostics14212441 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 31.10.2024. Verfasst von Sang Hyun Cho und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Veterans Health Service Medical Center, Seoul 05368, Republic of Korea. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: VHS Medical Center Research Grant, VHS Medical Center Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Fluoroscopy-guided PTNB for fluoroscopy-identifiable lung lesions has been suggested as a useful method for the pathological diagnosis of lung lesions; however, it is lacking in accuracy and safety compared to CT-guided PTNB. Thus, we aimed to investigate the diagnostic accuracy and complications of fluoroscopy-guided percutaneous transthoracic needle biopsy (PTNB) with the aid of pre-procedural planning cone-beam computed tomography (CBCT) in order to take advantage of their respective strengths.

Methods

A total of 255 fluoroscopy-guided PTNBs with the aid of planning CBCT were performed. Pre-procedural planning CBCT was conducted to calculate the shortest length from the skin puncture site to the margin of the target lesion for the needle trajectory. No intra-procedural CBCT was performed. The diagnostic performance of fluoroscopy-guided PTNB with the aid of planning CBCT was calculated. The prognostic factors for diagnostic failures and complications were evaluated using logistic regression analysis.

Results

The accuracy, sensitivity, specificity, PPV, and NPV were 97.3%, 88.0%, 90.9%, 100%, and 62.5%, respectively. There were 29 diagnostic failures (11.8%), and the multivariable analysis showed that a longer lesion depth on CBCT and a shorter specimen length were each associated with diagnostic failure (p = 0.010 and 0.012, respectively). Complications occurred in 34 PTNBs (13.3%). The multivariable analysis showed that an increased total number of biopsies per lesion, a longer length of lung aeration via needle insertion, a smaller lesion size on CT imaging (≤20 mm), and the presence of an air bronchogram were associated with the occurrence of complications (p = 0.027,

Schlagwörter

Stichwörter der Autor:innen

biopsycone-beam computed tomographyfluoroscopyimage-guided biopsylung

Autor:innen und Institutionen

  • Department of Radiology, Veterans Health Service Medical Center, Seoul 05368, Republic of Korea.
  • Veterans Medical Research Institute, Veterans Health Service Medical Center, Seoul 05368, Republic of Korea.

ORCID-Profile: Sang Hyun Cho, Hyun Jung Yoon, Young Lee, Yeo Jin Kim

Förderung

  • VHS Medical Center Research Grant
  • VHS Medical Center Research

Zitieren

APA

Cho, S. H., Yoon, H. J., Lee, Y., Kim, I., Gil, J. R., & Kim, Y. J. (2024). Fluoroscopy-Guided Percutaneous Transthoracic Needle Lung Biopsy with the Aid of Planning Cone-Beam CT: Diagnostic Accuracy and Complications. Diagnostics, 14(21), 2441. https://doi.org/10.3390/diagnostics14212441

Vancouver

Cho SH, Yoon HJ, Lee Y, Kim I, Gil JR, Kim YJ. Fluoroscopy-Guided Percutaneous Transthoracic Needle Lung Biopsy with the Aid of Planning Cone-Beam CT: Diagnostic Accuracy and Complications. Diagnostics. 2024;14(21):2441. doi:10.3390/diagnostics14212441

BibTeX
@article{Cho2024,
  author = {Cho, Sang Hyun and Yoon, Hyun Jung and Lee, Young and Kim, Injoong and Gil, Je Ryung and Kim, Yeo Jin},
  title = {Fluoroscopy-Guided Percutaneous Transthoracic Needle Lung Biopsy with the Aid of Planning Cone-Beam CT: Diagnostic Accuracy and Complications},
  journal = {Diagnostics},
  year = {2024},
  volume = {14},
  number = {21},
  pages = {2441},
  doi = {10.3390/diagnostics14212441}
}