EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Cone Beam CT Imaging-Guided Bronchoscopy vs CT Imaging-Guided Transthoracic Needle Biopsy for Peripheral Pulmonary Lesion Diagnosis

Pranjal Patel, David E Ost, Brian Shaller, Jiwoon Chang, Aishwarya Yenepalli, Hee Jae Choi, Dwayne Free, Cyra-Yoonsun Kang, Eric Sumner, Carrie Cao, Harmeet Bedi

CHEST · 2026-08 · 170 (2) · 604-618

DOI: 10.1016/j.chest.2026.02.038 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift CHEST, 2026-08. Verfasst von Pranjal Patel und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary, Allergy, and Critical Care Medicine, Stanford University, Stanford, CA. Electronic address: prapatel@stanford.edu. Hauptthemen laut MEDLINE: Image-Guided Biopsy, Bronchoscopy, Cone-Beam Computed Tomography, Lung Neoplasms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The identification of peripheral pulmonary lesions (PPLs) has increased significantly, either incidentally or through lung cancer screening, necessitating more biopsies to differentiate between malignant and benign causes. Cone beam CT imaging-guided bronchoscopic biopsy (CBCT-GB) and CT imaging-guided transthoracic needle biopsy (CT-TTNB) are used commonly for these biopsies, but their comparative diagnostic abilities have not been studied. RESEARCH QUESTION: How does CBCT-GB compare with CT-TTNB for diagnosing PPLs? STUDY DESIGN AND METHODS: This single-center retrospective comparative cohort study analyzed PPLs biopsied at an academic center via either CBCT-GB or CT-TTNB. The primary outcome was diagnostic accuracy at the 24-month follow-up, defined as the proportion of cases yielding a specific diagnosis (malignant or nonmalignant) or a nonspecific diagnosis that remained accurate through 24 months of clinical follow-up. Secondary outcomes included complication rates, procedure duration, radiation exposure, and the need for additional diagnostic procedures. RESULTS: Of 895 patients analyzed, 340 of 375 patients (90.7%) in the CBCT-GB group and 440 of 475 patients (92.6%) in the CT-TTNB group had a diagnostic result (P = .301; OR, 0.979; 95% CI, 0.939-1.020). Complications occurred in 4.3% of patients undergoing CBCT-GB and 41.6% of patients undergoing CT-TTNB (P < .001). Pneumothorax rates were 1.8% for CBCT-GB and 31.4% for CT-TTNB (P < .001), and severe bleeding or cardiorespiratory failure occurred in 3.3% and 6.0% of patients, respectively (P < .001). Among patients meeting criteria for upfront invasive mediastinal staging, 86.5% of patients undergoing CBCT-GB received it at the time of PPL biopsy, compared with 14.0% of patients after biopsy in the CT-TTNB group (P < .001). Median effective radiation dose was 8.6 mSv in the robotic bronchoscopy CBCT-GB group and 7.5 mSv in the CT-TTNB group (P =.074). INTERPRETATION: Our results show that CBCT-GB demonstrated a 24-month diagnostic accuracy comparable with that of CT-TTNB while offering improved safety and concurrent mediastinal lymph node staging. These data support CBCT-GB as the optimal initial procedure for PPL diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image-Guided BiopsyBronchoscopyCone-Beam Computed TomographyLung NeoplasmsLung DiseasesLungHumansFemaleRetrospective StudiesMaleMiddle AgedBiopsy, NeedleAgedTomography, X-Ray Computed

Stichwörter der Autor:innen

cone beam CT imagingdiagnostic accuracydiagnostic yieldgeneral radiologyinterventional pulmonologyinterventional radiologylung cancerlung noduleperipheral pulmonary lesionpulmonary critical carepulmonary nodulerobotic bronchoscopytransthoracic needle aspirationtransthoracic needle biopsy

Autor:innen und Institutionen

  • Division of Pulmonary, Allergy, and Critical Care Medicine, Stanford University, Stanford, CA. Electronic address: prapatel@stanford.edu.
  • Department of Pulmonary Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Division of Pulmonary, Allergy, and Critical Care Medicine, Stanford University, Stanford, CA.
  • Department of Pulmonary and Critical Care Medicine, University of California Davis Medical Center, Davis, CA.
  • Division of Pulmonary and Critical Care Medicine, University of North Carolina, Chapel Hill, NC.
  • Department of Respiratory Care, Stanford Health Care, Stanford, CA.

Zitieren

APA

Patel, P., Ost, D. E., Shaller, B., Chang, J., Yenepalli, A., Choi, H. J., Free, D., Kang, C. Y., Sumner, E., Cao, C., & Bedi, H. (2026). Cone Beam CT Imaging-Guided Bronchoscopy vs CT Imaging-Guided Transthoracic Needle Biopsy for Peripheral Pulmonary Lesion Diagnosis. CHEST, 170(2), 604-618. https://doi.org/10.1016/j.chest.2026.02.038

Vancouver

Patel P, Ost DE, Shaller B, Chang J, Yenepalli A, Choi HJ, et al. Cone Beam CT Imaging-Guided Bronchoscopy vs CT Imaging-Guided Transthoracic Needle Biopsy for Peripheral Pulmonary Lesion Diagnosis. CHEST. 2026;170(2):604-618. doi:10.1016/j.chest.2026.02.038

BibTeX
@article{Patel2026,
  author = {Patel, Pranjal and Ost, David E and Shaller, Brian and Chang, Jiwoon and Yenepalli, Aishwarya and Choi, Hee Jae and Free, Dwayne and Kang, Cyra-Yoonsun and Sumner, Eric and Cao, Carrie and Bedi, Harmeet},
  title = {Cone Beam CT Imaging-Guided Bronchoscopy vs CT Imaging-Guided Transthoracic Needle Biopsy for Peripheral Pulmonary Lesion Diagnosis},
  journal = {CHEST},
  year = {2026},
  volume = {170},
  number = {2},
  pages = {604--618},
  doi = {10.1016/j.chest.2026.02.038}
}
Kostenlos starten →