Influence of Anesthesiology Protocol on the Quality of Intraoperative Nerve Monitoring During Thyroid Surgery, One-Year Single Center Experience
Diagnostics · 22.10.2024 · 14 (21) · 2351
DOI: 10.3390/diagnostics14212351 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Diagnostics, online erschienen am 22.10.2024. Verfasst von Marina Stojanovic und 7 weiteren Autor:innen. Beteiligte Einrichtung: Medical Faculty, University of Belgrade, 11000 Belgrade, Serbia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and ICT, Ministry of Science, Technological Development and Innovation, University of Belgrade, School of Medicine.
Abstract (Originalsprache)
Background/Objectives: Anesthesia plays a very important role in the successful management of intraoperative neuromonitoring (IONM). The aim of our study was to investigate the impact of anesthesia induction and maintenance on the quality of signals during surgeries on the thyroid and parathyroid glands using neuromonitoring.
Methods
The study included 72 patients who underwent surgery with IONM for one year. All the patients were intubated using a Glidescope videolaryngoscope with a hyperangulated blade. Two different approaches were used to facilitate intubation: succinylcholine-1 mg/kg and rocuronium bromide-0.3 mg/kg. For anesthesia maintenance, total intravenous anesthesia (TIVA) or combined anesthesia was used. Patients’ body movements during operations, as well as electromyography signals from the vagus and recurrent laryngeal nerves before resection, were recorded as V1 and R1.
Results
Intraoperative unwanted movements were recorded in 25% of patients. Undesired movements were more frequently recorded in the TIVA group compared to the combined anesthesia group (p < 0.001) as well as in patients who received succinylcholine compared to patients who received rocuronium bromide (p = 0.028). Type of anesthesia maintenance as well as type of muscle relaxant did not affect the quality of recorded nerve signals. (p = 0.169 and p = 0.894, respectively).
Conclusions
The type of muscle relaxant used significantly affects the occurrence of undesirable movements during thyroid surgery with IONM, while the type of anesthesia maintenance did not influence either the quality of the obtained signal or the occurrence of undesirable movements.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Faculty, University of Belgrade, 11000 Belgrade, Serbia.
- Center for Anesthesiology and Resuscitation, University Clinical Center of Serbia, 11000 Belgrade, Serbia.
- Clinic for Endocrine Surgery, University Clinical Centre of Serbia, Pasterova 2, 11000 Belgrade, Serbia.
ORCID-Profile: Milan Jovanovic, Tanja Maravic, Branislav Rovcanin, Nikola Slijepcevic
Förderung
- Ministry of Science and ICT
- Ministry of Science, Technological Development and Innovation, University of Belgrade, School of Medicine
Zitieren
APA
Stojanovic, M., Jovanovic, M., Buzejic, M., Maravic, T., Rovcanin, B., Slijepcevic, N., Tausanovic, K., & Zivaljevic, V. (2024). Influence of Anesthesiology Protocol on the Quality of Intraoperative Nerve Monitoring During Thyroid Surgery, One-Year Single Center Experience. Diagnostics, 14(21), 2351. https://doi.org/10.3390/diagnostics14212351
Vancouver
Stojanovic M, Jovanovic M, Buzejic M, Maravic T, Rovcanin B, Slijepcevic N, et al. Influence of Anesthesiology Protocol on the Quality of Intraoperative Nerve Monitoring During Thyroid Surgery, One-Year Single Center Experience. Diagnostics. 2024;14(21):2351. doi:10.3390/diagnostics14212351
BibTeX
@article{Stojanovic2024,
author = {Stojanovic, Marina and Jovanovic, Milan and Buzejic, Matija and Maravic, Tanja and Rovcanin, Branislav and Slijepcevic, Nikola and Tausanovic, Katarina and Zivaljevic, Vladan},
title = {Influence of Anesthesiology Protocol on the Quality of Intraoperative Nerve Monitoring During Thyroid Surgery, One-Year Single Center Experience},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {21},
pages = {2351},
doi = {10.3390/diagnostics14212351}
}
EUVIMED