Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 16.09.2024. Verfasst von Sun Min Lee und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Inha University Hospital & College of Medicine, Incheon 22332, Republic of Korea. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Inha University.
Abstract (Originalsprache)
Background
With the advent of da Vinci SP, surgical methods using da Vinci SP are becoming popular in thyroid surgery. The authors previously reported on a new surgical method called the single-port robotic areolar (SPRA) approach, which evolved from the previous bilateral axillary breast approach (BABA). This paper reports a comparative analysis of SPRA and BABA over one year.
Methods
The data on SPRA and BABA thyroid surgery performed at the authors’ hospital from December 2022 to December 2023 were analyzed.
Results
111 SPRA and 159 BABA surgeries were performed. SPRA was performed overwhelmingly on women (1 man vs. 110 women), and the body mass index (BMI) was lower in SPRA patients (23.63 ± 3.49 vs. 25.71 ± 4.39, p < 0.001). The proportion of total thyroidectomy was significantly higher in BABA patients, and a modified radical neck dissection (MRND) was only performed using the BABA method. The time for flap formation before robot docking was significantly shorter in SPRA patients (12.08 ± 3.99 vs. 18.34 ± 5.84 min, p < 0.001). Postoperative drain amount was also significantly lower in SPRA patients (53.87 ± 35.45 vs. 81.74 ± 30.26 mL, p < 0.001). Hospital stay after surgery was significantly shorter with SPRA (3.04 ± 0.48 vs. 3.36 ± 0.73 days, p < 0.001). Thyroglobulin levels after a total thyroidectomy (0.06 ± 0.13 vs. 0.45 ± 0.78, p = 0.002) and stimulated Tg level before the RAI (1.03 ± 0.74 vs. 5.01 ± 13.63, p = 0.046) were significantly lower in the SPRA group. No significant differences were observed between the two groups according to the postoperative complications, including vocal cord palsy and hypoparathyroidism.
Conclusions
Based on the authors’ experience, SPRA is a less invasive robot thyroid surgery method than BABA.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, Inha University Hospital & College of Medicine, Incheon 22332, Republic of Korea.
- Robot Surgery Center, Inha University Hospital, Incheon 22332, Republic of Korea.
ORCID-Profile: Hilal Hwang, Jin Wook Yi
Förderung
- Inha University
Zitieren
APA
Lee, S. M., Hwang, H., Shin, M. H., & Yi, J. W. (2024). One-Year Clinical Experience of Single-Port and Multi-Port Robotic Thyroid Surgery in a Single Institution. Journal of Clinical Medicine, 13(18), 5486. https://doi.org/10.3390/jcm13185486
Vancouver
Lee SM, Hwang H, Shin MH, Yi JW. One-Year Clinical Experience of Single-Port and Multi-Port Robotic Thyroid Surgery in a Single Institution. Journal of Clinical Medicine. 2024;13(18):5486. doi:10.3390/jcm13185486
BibTeX
@article{Lee2024,
author = {Lee, Sun Min and Hwang, Hilal and Shin, Myung Ho and Yi, Jin Wook},
title = {One-Year Clinical Experience of Single-Port and Multi-Port Robotic Thyroid Surgery in a Single Institution},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
number = {18},
pages = {5486},
doi = {10.3390/jcm13185486}
}
EUVIMED