Comparison of Transient Elastography and Point Shear Wave Elastography for Analysis of Liver Stiffness: A Prospective Study
Diagnostics · 12.03.2024 · 14 (6) · 604
DOI: 10.3390/diagnostics14060604 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 12.03.2024. Verfasst von Giuseppe Losurdo und 11 weiteren Autor:innen. Beteiligte Einrichtung: Section of Gastroenterology, Department of Precision and Regenerative Medicine and Ionian Area, University of Bari, Piazza Giulio Cesare 11, 70124 Ba…. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Liver stiffness measurement (LSM) by Fibroscan is the most used non-invasive method to assess liver fibrosis. Recently, point-shear wave elastography (pSWE) has been introduced as a simple alternative non-invasive test. Therefore, we aimed to compare the results of these two techniques. One hundred and eighty-four consecutive patients attending our outpatient ultrasound clinic were recruited. LSM was performed by both Fibroscan and pSWE. Statistical analysis was conducted by Spearman’s test for correlation and linear regression. Bland–Altman graphs and ROC curves were drawn with area under the curve (AUC). Overall, the correlation of LS between Fibroscan and pSWE was substantial (r = 0.68, p < 0.001). Linear regression showed a coefficient b= 0.94 ± 0.02. The Bland–Altman plot found a bias of −0.10, with only 11 values exceeding the 95% confidence interval. When only considering patients with a LSM of > 10 kPa (n = 31), we found an excellent r = 0.79 (0.60–0.90, p < 0.001). A cutoff of 12.15 kPa for pSWE had sensitivity = 74.2% and specificity = 99.3% to detect relevant fibrosis, with an AUC = 0.98. The highest correlation was observed for hepatitis C (r = 0.91) and alcoholic liver disease (ALD)(r = 0.99). In conclusion, pSWE shows LSM estimation in agreement with Fibroscan in most cases, and the best concordance was observed for hepatitis C and ALD, and for higher ranges of LS.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Section of Gastroenterology, Department of Precision and Regenerative Medicine and Ionian Area, University of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy.
- Ph.D. Course in Organs and Tissues Transplantation and Cellular Therapies, Department of Precision and Regenerative Medicine and Ionian Area, University of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy.
ORCID-Profile: Giuseppe Losurdo, Domenico Novielli, Francesca Celiberto, Antonino Castellaneta, Michele Barone, Enzo Ierardi, Alfredo Di Leo
Zitieren
APA
Losurdo, G., Ditonno, I., Novielli, D., Celiberto, F., Iannone, A., Castellaneta, A., Dell'Aquila, P., Ranaldo, N., Rendina, M., Barone, M., Ierardi, E., & Di Leo, A. (2024). Comparison of Transient Elastography and Point Shear Wave Elastography for Analysis of Liver Stiffness: A Prospective Study. Diagnostics, 14(6), 604. https://doi.org/10.3390/diagnostics14060604
Vancouver
Losurdo G, Ditonno I, Novielli D, Celiberto F, Iannone A, Castellaneta A, et al. Comparison of Transient Elastography and Point Shear Wave Elastography for Analysis of Liver Stiffness: A Prospective Study. Diagnostics. 2024;14(6):604. doi:10.3390/diagnostics14060604
BibTeX
@article{Losurdo2024,
author = {Losurdo, Giuseppe and Ditonno, Ilaria and Novielli, Domenico and Celiberto, Francesca and Iannone, Andrea and Castellaneta, Antonino and Dell'Aquila, Paola and Ranaldo, Nunzio and Rendina, Maria and Barone, Michele and Ierardi, Enzo and Di Leo, Alfredo},
title = {Comparison of Transient Elastography and Point Shear Wave Elastography for Analysis of Liver Stiffness: A Prospective Study},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {6},
pages = {604},
doi = {10.3390/diagnostics14060604}
}
EUVIMED