Whole Process of Standardization of Diffusion-Weighted Imaging: Phantom Validation and Clinical Application According to the QIBA Profile
Diagnostics · 09.03.2024 · 14 (6) · 583
DOI: 10.3390/diagnostics14060583 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 09.03.2024. Verfasst von Se Jin Choi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of K…. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Korea Health Industry Development Institute.
Abstract (Originalsprache)
Background
To use the apparent diffusion coefficient (ADC) as reliable biomarkers, validation of MRI equipment performance and clinical acquisition protocols should be performed prior to application in patients. This study aims to validate various MRI equipment and clinical brain protocols for diffusion weighted imaging (DWI) using commercial phantom, and confirm the validated protocols in patients’ images.
Methods
The performance of four different scanners and clinical brain protocols were validated using a Quantitative Imaging Biomarker Alliance (QIBA) diffusion phantom and cloud-based analysis tool. We evaluated the performance metrics regarding accuracy and repeatability of ADC measurement using QIBA profile. The validated clinical brain protocols were applied to 17 patients, and image quality and repeatability of ADC were assessed.
Results
The MRI equipment performance of all four MRI scanners demonstrated high accuracy in ADC measurement (ADC bias, −2.3% to −0.4%), excellent linear correlation to the reference ADC value (slope, 0.9 to 1.0; R2, 0.999–1.000), and high short-term repeatability [within-subject-coefficient-of-variation (wCV), 0% to 0.3%]. The clinical protocols were also validated by fulfilling QIBA claims with high accuracy (ADC bias, −3.1% to −0.7%) and robust repeatability (wCV, 0% to 0.1%). Brain DWI acquired using the validated clinical protocols showed ideal image quality (mean score ≥ 2.9) and good repeatability (wCV, 1.8–2.2).
Conclusions
The whole process of standardization of DWI demonstrated the robustness of ADC with high accuracy and repeatability across diverse MRI equipment and clinical protocols in accordance with the QIBA claims.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea.
- Biomedical Research Center, Asan Institute for Life Sciences, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea.
- Department of Radiology, Asan Medical Institute of Convergence Science and Technology (AMIST), Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea.
ORCID-Profile: Se Jin Choi, Kyung Won Kim, Ji Sung Jang
Förderung
- National Research Foundation of Korea
- Korea Health Industry Development Institute
Zitieren
APA
Choi, S. J., Kim, K. W., Ko, Y., Cho, Y. C., Jang, J. S., Ahn, H., Kim, D. W., & Kim, M. Y. (2024). Whole Process of Standardization of Diffusion-Weighted Imaging: Phantom Validation and Clinical Application According to the QIBA Profile. Diagnostics, 14(6), 583. https://doi.org/10.3390/diagnostics14060583
Vancouver
Choi SJ, Kim KW, Ko Y, Cho YC, Jang JS, Ahn H, et al. Whole Process of Standardization of Diffusion-Weighted Imaging: Phantom Validation and Clinical Application According to the QIBA Profile. Diagnostics. 2024;14(6):583. doi:10.3390/diagnostics14060583
BibTeX
@article{Choi2024,
author = {Choi, Se Jin and Kim, Kyung Won and Ko, Yousun and Cho, Young Chul and Jang, Ji Sung and Ahn, Hyemin and Kim, Dong Wook and Kim, Mi Young},
title = {Whole Process of Standardization of Diffusion-Weighted Imaging: Phantom Validation and Clinical Application According to the QIBA Profile},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {6},
pages = {583},
doi = {10.3390/diagnostics14060583}
}
EUVIMED