EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Agreement between Fetal Brain Ultrasonography and Magnetic Resonance Imaging in the Measurements of the Corpus Callosum and Transverse Cerebellar Diameter

Shai Bookstein iD, Noy Nachmias iD, Eldad Katorza

Diagnostics · 2024-02-07 · 14 (4) · 366

DOI: 10.3390/diagnostics14040366 ↗

At a glance

Journal article in Diagnostics, published online on 2024-02-07. Written by Shai Bookstein and 2 co-authors. Institution: Antenatal Diagnostic Unit, Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel-Hashomer, Derech Sheba 2, Ramat Gan 5262000, Isra…. Cited 3 times so far (Crossref); 22 references. The full text is freely available (open access, CC BY 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

As the use of magnetic resonance imaging of the fetal brain has evolved, the need to understand its efficiency in the biometry of the fetal brain has broadened. This study aimed to assess the level of agreement and correlation between the two cardinal imaging methods of fetal neuroimaging, ultrasonography (US) and magnetic resonance imaging (MRI), by measuring the corpus callosum (CC) and transverse cerebellar diameter (TCD) in terms of length and percentile. Measurements of CC and TCD length and percentile were documented over a 7-year span in a tertiary referral medical center. All US and MRI examinations were performed in the customary planes and subcategorized by valid reference charts. Exclusion and inclusion criteria were set before the collection and processing of the data. A total of 156 fetuses out of 483 were included in the study. A positive, strong correlation and agreement were found (r = 0.78; ICC = 0.76) between US and MRI in TCD measurements. For CC length measurement, a moderate correlation and moderate agreement (r = 0.51; ICC = 0.49) between US and MRI was observed. TCD and CC percentiles had lower levels of correlation and agreement compared with the length variables. Our study indicates good agreement between MRI and US in the assessment of TCD measurement as a part of antenatal neuroimaging. Furthermore, while the two techniques are not always compatible, they are complementary methods.

Subjects

Author keywords

MRIcerebellumcorpus callosumfetal brainneurodevelopment

Authors and institutions

  • Antenatal Diagnostic Unit, Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel-Hashomer, Derech Sheba 2, Ramat Gan 5262000, Israel.
  • Faculty of Medicine, Tel Aviv University, Klatchkin 35, Tel Aviv 6139001, Israel.
  • Gertner Institute for Epidemiology & Health Policy Research, Chaim Sheba Medical Center, Tel-Hashomer, Derech Sheba 2, Ramat Gan 5262000, Israel.
  • Arrow Program for Medical Research Education, Chaim Sheba Medical Center, Tel-Hashomer, Derech Sheba 2, Ramat Gan 5262000, Israel.

ORCID profiles: Shai Bookstein, Noy Nachmias

Cite

APA

Bookstein, S., Nachmias, N., & Katorza, E. (2024). Agreement between Fetal Brain Ultrasonography and Magnetic Resonance Imaging in the Measurements of the Corpus Callosum and Transverse Cerebellar Diameter. Diagnostics, 14(4), 366. https://doi.org/10.3390/diagnostics14040366

Vancouver

Bookstein S, Nachmias N, Katorza E. Agreement between Fetal Brain Ultrasonography and Magnetic Resonance Imaging in the Measurements of the Corpus Callosum and Transverse Cerebellar Diameter. Diagnostics. 2024;14(4):366. doi:10.3390/diagnostics14040366

BibTeX
@article{Bookstein2024,
  author = {Bookstein, Shai and Nachmias, Noy and Katorza, Eldad},
  title = {Agreement between Fetal Brain Ultrasonography and Magnetic Resonance Imaging in the Measurements of the Corpus Callosum and Transverse Cerebellar Diameter},
  journal = {Diagnostics},
  year = {2024},
  volume = {14},
  number = {4},
  pages = {366},
  doi = {10.3390/diagnostics14040366}
}
Start for free →