EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of Breathing Phase, Liver Segment, and Prandial State on Ultrasound Shear Wave Speed, Shear Wave Dispersion, and Attenuation Imaging of the Liver in Healthy Volunteers

Catherine Paverd, Sivert Kupfer, Iara Nascimento Kirchner, Sherin Nambiar, Alexander Martin, Naiara Korta Martiartu iD, Thomas Frauenfelder iD, Marga B Rominger, Lisa Ruby

Diagnostics · 05.03.2023 · 13 (5) · 989

DOI: 10.3390/diagnostics13050989 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 05.03.2023. Verfasst von Catherine Paverd und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Canon Medical Systems Corporation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Measurement location and patient state can impact noninvasive liver assessment and change clinical staging in ultrasound examinations. Research into differences exists for Shear Wave Speed (SWS) and Attenuation Imaging (ATI), but not for Shear Wave Dispersion (SWD). The aim of this study is to assess the effect of breathing phase, liver lobe, and prandial state on SWS, SWD, and ATI ultrasound measurements.

Methods

Two experienced examiners performed SWS, SWD, and ATI measurements in 20 healthy volunteers using a Canon Aplio i800 system. Measurements were taken in the recommended condition (right lobe, following expiration, fasting state), as well as (a) following inspiration, (b) in the left lobe, and (c) in a nonfasting state.

Results

SWS and SWD measurements were strongly correlated (r = 0.805, p < 0.001). Mean SWS was 1.34 ± 0.13 m/s in the recommended measurement position and did not change significantly under any condition. Mean SWD was 10.81 ± 2.05 m/s/kHz in the standard condition and significantly increased to 12.18 ± 1.41 m/s/kHz in the left lobe. Individual SWD measurements in the left lobe also had the highest average coefficient of variation (19.68%). No significant differences were found for ATI.

Conclusion

Breathing and prandial state did not significantly affect SWS, SWD, and ATI values. SWS and SWD measurements were strongly correlated. SWD measurements in the left lobe showed a higher individual measurement variability. Interobserver agreement was moderate to good.

Schlagwörter

Stichwörter der Autor:innen

attenuation imagingshear wave dispersionshear wave elastographyshear wave speedultrasound liver assessment

Autor:innen und Institutionen

  • Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland.
  • Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland.

ORCID-Profile: Naiara Korta Martiartu, Thomas Frauenfelder

Förderung

  • Canon Medical Systems Corporation

Zitieren

APA

Paverd, C., Kupfer, S., Kirchner, I. N., Nambiar, S., Martin, A., Korta Martiartu, N., Frauenfelder, T., Rominger, M. B., & Ruby, L. (2023). Impact of Breathing Phase, Liver Segment, and Prandial State on Ultrasound Shear Wave Speed, Shear Wave Dispersion, and Attenuation Imaging of the Liver in Healthy Volunteers. Diagnostics, 13(5), 989. https://doi.org/10.3390/diagnostics13050989

Vancouver

Paverd C, Kupfer S, Kirchner IN, Nambiar S, Martin A, Korta Martiartu N, et al. Impact of Breathing Phase, Liver Segment, and Prandial State on Ultrasound Shear Wave Speed, Shear Wave Dispersion, and Attenuation Imaging of the Liver in Healthy Volunteers. Diagnostics. 2023;13(5):989. doi:10.3390/diagnostics13050989

BibTeX
@article{Paverd2023,
  author = {Paverd, Catherine and Kupfer, Sivert and Kirchner, Iara Nascimento and Nambiar, Sherin and Martin, Alexander and Korta Martiartu, Naiara and Frauenfelder, Thomas and Rominger, Marga B and Ruby, Lisa},
  title = {Impact of Breathing Phase, Liver Segment, and Prandial State on Ultrasound Shear Wave Speed, Shear Wave Dispersion, and Attenuation Imaging of the Liver in Healthy Volunteers},
  journal = {Diagnostics},
  year = {2023},
  volume = {13},
  number = {5},
  pages = {989},
  doi = {10.3390/diagnostics13050989}
}
Kostenlos starten →