EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Shear wave elastography and shear wave dispersion correlated to biopsy at the scheduled follow‐up of pediatric liver grafts

Ivan Cetinic iD, Charlotte de Lange iD, Håkan Boström, Nils Ekvall, William Bennet iD, Kerstin Lagerstrand iD, Hanna Hebelka iD

Pediatric Transplantation · 2023-11 · 27 (7)

DOI: 10.1111/petr.14591 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Transplantation, online erschienen am 15.08.2023. Verfasst von Ivan Cetinic und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver Transplantation, Liver, Liver Cirrhosis. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Åke Wiberg Stiftelse, Göteborgs Läkarsällskap, Konrad and Helfrid Johanssons Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

It is unknown how shear wave dispersion (SWD) is displayed in pediatric liver transplant recipients and not fully elucidated how ultrasound shear wave elastography (2D‐SWE) display within this cohort, which is important to determine to improve noninvasive surveillance of these patients. The study aimed to compare SWE and SWD values with histopathology in pediatric liver recipients.

Methods

Forty‐eight pediatric liver recipients were examined with SWE in conjunction with an elective liver biopsy (clinically without complication). Additionally, SWD values were measured in 21 children. SWE and SWD values were compared to histologically determined fibrosis graded as none‐to‐mild (F0–1) and moderate‐to‐severe (F2–4), and inflammation graded as low (grade 0–1) and high (grade 2–4).

Results

Two children were excluded due to SWE IQR/median > 30% kPa. The mean age across 46 included patients was 10.9 years (range 1.4–18). The number of patients and median (range) SWE value (kPa) for each stage of fibrosis were: F0–1 [ n = 23; 5.8 (3.2–16.1)], F2 [ n = 22; 6.0 (4.5–25.9)], F3 [ n = 1; 33.3], and F4 [ n = 0]. Significantly higher SWE values and greater variability were registered in F2–4 vs. F0–1 ( p = .05). Grade of fibrosis correlated weakly to SWE values ( r = .3; p = .05), but not to SWD values ( r = .2; p = .27). In patients with low‐grade inflammation, median SWD was 13.7 m/s KHz (10.7–17.6). Only one patient had high‐grade inflammation.

Conclusions

Uncomplicated transplanted liver grafts in a small pediatric cohort revealed slightly increased SWE and SWD values compared to previously reported values in healthy children. This likely reflect both the fibrotic and inflammatory elements in the grafts; however, other confounders impacting the liver's viscoelastic properties are also probable factors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesLiver TransplantationLiverLiver CirrhosisHumansChildMaleFemaleAdolescentChild, PreschoolBiopsyInfantFollow-Up Studies

Stichwörter der Autor:innen

Liver biopsyfibrosisinflammationpediatric liver transplantsshear wave dispersionshear wave elastography

Autor:innen und Institutionen

  • Department of Pediatric Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Institution of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Department of Pediatric Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Department of Transplantation Surgery, Sahlgrenska University Hospital Gothenburg, Gothenburg, Sweden.
  • Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden.

ORCID-Profile: Ivan Cetinic, Charlotte de Lange, William Bennet, Kerstin Lagerstrand, Hanna Hebelka

Förderung

  • Åke Wiberg Stiftelse
  • Göteborgs Läkarsällskap
  • Konrad and Helfrid Johanssons Research Foundation
  • Stiftelsen Samariten
  • Stiftelsen Sven Jerrings Fond
  • The study was financed by grants from the Swedish state under the agreement between the Swedish Government and the county concils, the ALF-agreement (ange ansl…

Zitieren

APA

Cetinic, I., de Lange, C., Boström, H., Ekvall, N., Bennet, W., Lagerstrand, K., & Hebelka, H. (2023). Shear wave elastography and shear wave dispersion correlated to biopsy at the scheduled follow‐up of pediatric liver grafts. Pediatric Transplantation, 27(7). https://doi.org/10.1111/petr.14591

Vancouver

Cetinic I, de Lange C, Boström H, Ekvall N, Bennet W, Lagerstrand K, et al. Shear wave elastography and shear wave dispersion correlated to biopsy at the scheduled follow‐up of pediatric liver grafts. Pediatric Transplantation. 2023;27(7). doi:10.1111/petr.14591

BibTeX
@article{Cetinic2023,
  author = {Cetinic, Ivan and de Lange, Charlotte and Boström, Håkan and Ekvall, Nils and Bennet, William and Lagerstrand, Kerstin and Hebelka, Hanna},
  title = {Shear wave elastography and shear wave dispersion correlated to biopsy at the scheduled follow‐up of pediatric liver grafts},
  journal = {Pediatric Transplantation},
  year = {2023},
  volume = {27},
  number = {7},
  doi = {10.1111/petr.14591}
}
Kostenlos starten →