EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An In Vitro Investigation of Gas and Dye Leakage at the Implant–Abutment Junction Using Titanium and Cobalt Chrome-Based Abutments

Amylia Kesha Bal, Terry Richard Walton, Hedi Verena Kruse, Dale Geoffrey Howes

Coatings · 22.03.2026 · 16 (3) · 388

DOI: 10.3390/coatings16030388 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Coatings, online erschienen am 22.03.2026. Verfasst von Amylia Kesha Bal und 3 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australasian Osseointegration Society (AOS) NSW Branch, Australian Prosthodontic Society (APS) Federal.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The lack of integrity at the implant–abutment junction (IAJ) contributes to problems such as micromovements and microbial colonisation. This study aimed to (1) design a protocol for assessing microleakage at the IAJ using chromophore analysis not previously reported for this specific application, (2) compare gas and dye leakage between titanium (Ti) and cobalt chrome (CoCr) abutments, and (3) assess the effect of gold (Au) gilding on sealing. Forty abutments were divided into five groups: milled Ti (MTi); cast CoCr (CCoCr); milled CoCr (MCoCr); cast CoCr with Au gilding (CCoCrG); and milled CoCr with Au gilding (MCoCrG). Samples were subjected to internal pressure within a gas and dye reservoir. Chromophore analysis via UV-Vis spectrometer was used to calculate crystal violet leakage concentrations. Scanning electron microscopy (SEM) revealed close adaptation in the MTi and MCoCr groups, contrasting with irregularities in the CCoCr groups. Correspondingly, gas leakage and dye leakage were most prevalent in the CCoCr group. Fisher exact test demonstrated a statistically significant difference (p = 0.026) between the MCoCr and CCoCr abutments. While CCoCr exhibited the highest failure rate (62.5%), Au gilding demonstrated a trend toward reduced leakage (25% failure rate), though this did not reach statistical significance (p = 0.315). This chromophore analysis represents a viable and objective assessment of IAJ integrity.

Förderung

  • Australasian Osseointegration Society (AOS) NSW Branch
  • Australian Prosthodontic Society (APS) Federal

Zitieren

APA

Bal, A. K., Walton, T. R., Kruse, H. V., & Howes, D. G. (2026). An In Vitro Investigation of Gas and Dye Leakage at the Implant–Abutment Junction Using Titanium and Cobalt Chrome-Based Abutments. Coatings, 16(3), 388. https://doi.org/10.3390/coatings16030388

Vancouver

Bal AK, Walton TR, Kruse HV, Howes DG. An In Vitro Investigation of Gas and Dye Leakage at the Implant–Abutment Junction Using Titanium and Cobalt Chrome-Based Abutments. Coatings. 2026;16(3):388. doi:10.3390/coatings16030388

BibTeX
@article{Bal2026,
  author = {Bal, Amylia Kesha and Walton, Terry Richard and Kruse, Hedi Verena and Howes, Dale Geoffrey},
  title = {An In Vitro Investigation of Gas and Dye Leakage at the Implant–Abutment Junction Using Titanium and Cobalt Chrome-Based Abutments},
  journal = {Coatings},
  year = {2026},
  volume = {16},
  number = {3},
  pages = {388},
  doi = {10.3390/coatings16030388}
}
Kostenlos starten →