Mechanistic Analysis of Anodic Oxidation of Gold in KOH (0.1 M) Solution Using the Point Defect Model
Corrosion and Materials Degradation · 2024-10-09 · 5 (4) · 450-475
DOI: 10.3390/cmd5040021 ↗At a glance
Journal article in Corrosion and Materials Degradation, published online on 2024-10-09. Written by Zahed Ghelichkhah and 2 co-authors. Cited 4 times so far (Crossref); 42 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
The potentiostatic, anodic formation of gold oxide at potentials of 0.55 to 0.80 V versus SHE in aqueous KOH (0.1 M) was studied using an impedance-based Point Defect Model (PDM). The film thickness and refractive indices at each formation potential were estimated using spectroscopic ellipsometry. The thickness of the oxide increases linearly with increasing applied voltage within this range. Mott-Schottky (MS) analysis showed that gold oxide formed in KOH (0.1 M) is an n-type semiconductor, and the dominant defect (Aui3+) density is calculated to be in the order of 1021–1022 (1/cm3). The steady-state current density of the oxide formation was independent of voltage, also in agreement with an n-type oxide. Reasonable agreement between PDM predictions and experimental observations of dominant defect density, steady-state current density, and thickness, demonstrates the value of the PDM in this system.
Cite
APA
Ghelichkhah, Z., Macdonald, D. D., & Ferguson, G. S. (2024). Mechanistic Analysis of Anodic Oxidation of Gold in KOH (0.1 M) Solution Using the Point Defect Model. Corrosion and Materials Degradation, 5(4), 450-475. https://doi.org/10.3390/cmd5040021
Vancouver
Ghelichkhah Z, Macdonald DD, Ferguson GS. Mechanistic Analysis of Anodic Oxidation of Gold in KOH (0.1 M) Solution Using the Point Defect Model. Corrosion and Materials Degradation. 2024;5(4):450-475. doi:10.3390/cmd5040021
BibTeX
@article{Ghelichkhah2024,
author = {Ghelichkhah, Zahed and Macdonald, Digby D. and Ferguson, Gregory S.},
title = {Mechanistic Analysis of Anodic Oxidation of Gold in KOH (0.1 M) Solution Using the Point Defect Model},
journal = {Corrosion and Materials Degradation},
year = {2024},
volume = {5},
number = {4},
pages = {450--475},
doi = {10.3390/cmd5040021}
}